1993
DOI: 10.1213/00000539-199311000-00008
|View full text |Cite
|
Sign up to set email alerts
|

Epidural Anesthesia for Labor in an Ambulatory Patient

Abstract: The effectiveness of two epidural analgesic regimens on the ability to ambulate was compared in women in labor by a prospective, randomized, double-blind design. One group of patients received epidural fentanyl, a 75-micrograms bolus and an infusion of fentanyl 2.5 micrograms/mL at 15 mL/h (FENT, n = 53). A second group received ultra low-dose bupivacaine (0.04%), epinephrine (1.7 micrograms/mL), and fentanyl (1.7 micrograms/mL) (BEF, n = 77), a 15-mL bolus followed by an infusion at 15 mL/h. Adequate analgesi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

11
142
4

Year Published

1995
1995
2018
2018

Publication Types

Select...
7
2
1

Relationship

1
9

Authors

Journals

citations
Cited by 234 publications
(157 citation statements)
references
References 17 publications
11
142
4
Order By: Relevance
“…There were no differences in systolic blood pressure (P = 0.127) or heart rate (P = 0.831) over time between groups. Time to a modified Bromage score of 2 was longer in Group S than in Group L [101 (15) min vs 88 (14) min, respectively; P \ 0.001]. Conclusions Sitting the patient up for five minutes rather than laying the patient down immediately after spinal anesthesia for Cesarean delivery decreased intraoperative sensory block height, ephedrine and fluid requirements, and intraoperative nausea, vomiting, and shortness of breath without affecting systolic blood pressure or the success of the anesthetic.…”
Section: Introductionmentioning
confidence: 97%
“…There were no differences in systolic blood pressure (P = 0.127) or heart rate (P = 0.831) over time between groups. Time to a modified Bromage score of 2 was longer in Group S than in Group L [101 (15) min vs 88 (14) min, respectively; P \ 0.001]. Conclusions Sitting the patient up for five minutes rather than laying the patient down immediately after spinal anesthesia for Cesarean delivery decreased intraoperative sensory block height, ephedrine and fluid requirements, and intraoperative nausea, vomiting, and shortness of breath without affecting systolic blood pressure or the success of the anesthetic.…”
Section: Introductionmentioning
confidence: 97%
“…Sensation to pinprick using a Neuropen Ò (Owen Mumford Ltd, Woodstock, UK) was measured at 20 min and again at 60 and 120 min. Additional measurements at 20, 60, and 120 min included the presence of motor block, 8 and the presence and severity of nausea, pruritus, and sedation, assessed as described above. 9 The fetal heart rate was continuously monitored by cardiotocography, and adverse events documented by the clinical care team were recorded.…”
Section: Methodsmentioning
confidence: 99%
“…Motor block was assessed bilaterally at the same time interval using Modified Bromage scale. 6,7 (0=no paralysis-full flexion of hip, knee, ankle. 1= Unable to flex hip, able to flex knee and ankle, 2=unable to flex hip and knee.…”
Section: Exclusion Criteriamentioning
confidence: 99%