1982
DOI: 10.1109/mper.1982.5521054
|View full text |Cite
|
Sign up to set email alerts
|

EPPC - A Computer Program for Six-Phase Transmission Line Design

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

1995
1995
2020
2020

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 0 publications
0
6
0
Order By: Relevance
“…The proposed data mining-based protection strategy has been implemented for a six-phase two-end power network referring to the Springdale-McCalmont 138 kV, 60 Hz line of 68-km length (Figure 1). 22 The specifications of the Allegheny Power System (APS) network have been adopted in the present work for simulating the six-phase system. The source impedance of sending and receiving end are 2.03 + j9.04 Ω and 4 + j17.94 Ω, respectively.…”
Section: Power System Studiedmentioning
confidence: 99%
“…The proposed data mining-based protection strategy has been implemented for a six-phase two-end power network referring to the Springdale-McCalmont 138 kV, 60 Hz line of 68-km length (Figure 1). 22 The specifications of the Allegheny Power System (APS) network have been adopted in the present work for simulating the six-phase system. The source impedance of sending and receiving end are 2.03 + j9.04 Ω and 4 + j17.94 Ω, respectively.…”
Section: Power System Studiedmentioning
confidence: 99%
“…(1) (2) (4) IIXII > 0 for X f 0 and IIOII = 0 1 1 cx 1 1 = 1 c 1 1 1 x 11, for any scalar multiplier 'c'…”
Section: B Properties Of Vector and Matrix Normsmentioning
confidence: 99%
“…Since then it has received wide consideration and feasibility reports have been prepared for Allegheny Power by Venkata and others [2,3,4]. Stewart, Wilson and others have made extensive studies on many aspects of HPO transmission [5,6,7].…”
Section: Introductionmentioning
confidence: 99%
“…SPT system also offers several benefits over three phase transmission (TPT) system such as lower audible noise levels, lesser corona, decreased radio interference levels, reduced conductor surface gradient, good voltage regulation, higher efficiency, better surge impedance loading and thermal loading capacity. The SPT line theory and benefits are demonstrated in the literature 1,2,3,4,5,6 . The DCTPT line is converted into a single circuit SPT line successfully 7 .…”
Section: Introductionmentioning
confidence: 99%