1994
DOI: 10.1016/0969-8043(94)90050-7
|View full text |Cite
|
Sign up to set email alerts
|

Equilibrium and non-equilibrium partition of tritium between organics and tissue water of different biological systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
10
0
1

Year Published

2002
2002
2019
2019

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 27 publications
(12 citation statements)
references
References 32 publications
1
10
0
1
Order By: Relevance
“…Conventional OBT extraction methods involve a commercial combustion apparatus (Bogen et al, 1973;Brudenell et al, 1997;Garland and Ameen, 1979;Guenot and Belot, 1984;Kim and Baumgä rtner, 1994). The principle of our device provided by Eraly has been described in the literature (Baglan et al, 2005;Pointurier et al, 2003Pointurier et al, , 2004.…”
Section: Non-exchangeable Obtmentioning
confidence: 99%
“…Conventional OBT extraction methods involve a commercial combustion apparatus (Bogen et al, 1973;Brudenell et al, 1997;Garland and Ameen, 1979;Guenot and Belot, 1984;Kim and Baumgä rtner, 1994). The principle of our device provided by Eraly has been described in the literature (Baglan et al, 2005;Pointurier et al, 2003Pointurier et al, , 2004.…”
Section: Non-exchangeable Obtmentioning
confidence: 99%
“…Ceci révèle une diffusion de l'eau de l'air vers l'eau contenue dans la plante, principalement à travers les stomates, malgré un flux d'eau essentiellement sortant. Cette fraction est notée TFWT pour « Tissue Free Water Tritium » (Kim et Baumgärtner, 1994). Chez l'animal et l'homme, après absorption unique d'eau tritiée, l'activité maximale en eau tritiée du milieu intérieur (et des urines) est également atteinte en quelques heures, et la période biologique d'élimination est de l'ordre de quelques jours à la dizaine de jours (Galeriu et al, 2008 ;Galeriu et Melintescu, 2011).…”
Section: Transport Atmosphérique Et Dépôtunclassified
“…Carbon bound tritium is far less significant after an acute contamination, and its measurement needs to eliminate totally the exchangeable tritium, which is a source of technical difficulties. Other overestimation may come from "buried water" in macromolecules included as carbon bound tritium (Kim and Baumgärtner, 1994). As the dose per unit intake conversion factor given by the International Commission on Radiological Protection (ICRP, 1989) supposes 50% of exchangeable tritium in organic matter, the best method is to remain consistent with this approach.…”
Section: Production Of Tritiated Organic Mattermentioning
confidence: 99%