2010
DOI: 10.1134/s1087659610010177
|View full text |Cite
|
Sign up to set email alerts
|

Equipment for investigations of biological nanostructures by diffraction methods using synchrotron radiation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2012
2012
2018
2018

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 12 publications
0
5
0
Order By: Relevance
“…SAXS Measurements. SAXS experiments were performed on the DICSY synchrotron beamline (NRC Kurchatov Institute, Moscow) 28 at a constant wavelength of 1.62 Å. SAXS patterns were obtained using a Pilatus3 1M detector with a sample-to-detector distance of 300 mm and an exposure time of 5 min. The primary beam was collimated using a three-slit scheme, which provided a cross-sectional beam size of approximately 0.4 × 0.6 mm 2 on the sample.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
“…SAXS Measurements. SAXS experiments were performed on the DICSY synchrotron beamline (NRC Kurchatov Institute, Moscow) 28 at a constant wavelength of 1.62 Å. SAXS patterns were obtained using a Pilatus3 1M detector with a sample-to-detector distance of 300 mm and an exposure time of 5 min. The primary beam was collimated using a three-slit scheme, which provided a cross-sectional beam size of approximately 0.4 × 0.6 mm 2 on the sample.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
“…X ray diffraction stations were equipped with vari ous systems of detection: fast response one coordi nate detectors (9) [16,22]; Image Plate memory V mo X V mi X screens with the corresponding analyzer (10); and two coordinate detectors (11) with cooled CCD matrices, where the images from the X ray fluorescent screens were transferred with the use of optics [22] or fiber optics [23].…”
Section: Results Of Instrumental and Methodical Developmentsmentioning
confidence: 99%
“…Several versions of this procedure were designed with the set of the pro grams of experimental control and data gathering and processing. In subsequent years, its modernization on various SR sources was performed [16,22]. The exper iments were conducted both at the dynamic and static mode looking through the development of the response of objects over time on various physicochem ical actions.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations