2013
DOI: 10.1120/jacmp.v14i5.4340
|View full text |Cite
|
Sign up to set email alerts
|

Equivalent square formula for determining the surface dose of rectangular field from 6 MV therapeutic photon beam

Abstract: The purpose of the study was to investigate the use of the equivalent square formula for determining the surface dose from a rectangular photon beam. A 6 MV therapeutic photon beam delivered from a Varian Clinac 23EX medical linear accelerator was modeled using the EGS4nrc Monte Carlo simulation package. It was then used to calculate the dose in the build‐up region from both square and rectangular fields. The field patterns were defined by various settings of the X‐ and Y‐collimator jaw ranging from 5 to 20 cm… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2016
2016
2016
2016

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 15 publications
0
1
0
Order By: Relevance
“…With an increasing energy of these radiations, the penetration power of photons and secondary electrons will be increased and as a result the point of maximum dose (d_max) is placed in more depth (Apipunyasopon et al, 2013).Depending on the amount of energy, dose build up region occurs for x-rays megavoltage in the first depths of the entrance surface of phantom or skin. Dose build up region are a causes the skin sparing effect in megavoltage beams and makes them suitable for delivering the lethal dose to deep tumors as well as reaching the lowest dose in the surface layers of the skin (Butson et al, 1997;Ravikumar and Ravichandran, 2000).…”
Section: Introductionmentioning
confidence: 99%
“…With an increasing energy of these radiations, the penetration power of photons and secondary electrons will be increased and as a result the point of maximum dose (d_max) is placed in more depth (Apipunyasopon et al, 2013).Depending on the amount of energy, dose build up region occurs for x-rays megavoltage in the first depths of the entrance surface of phantom or skin. Dose build up region are a causes the skin sparing effect in megavoltage beams and makes them suitable for delivering the lethal dose to deep tumors as well as reaching the lowest dose in the surface layers of the skin (Butson et al, 1997;Ravikumar and Ravichandran, 2000).…”
Section: Introductionmentioning
confidence: 99%