2016
DOI: 10.1103/physreva.94.029905
|View full text |Cite
|
Sign up to set email alerts
|

Erratum: Polarization measurement of dielectronic recombination transitions in highly charged krypton ions [Phys. Rev. A92, 042702 (2015)]

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
7
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 0 publications
1
7
0
Order By: Relevance
“…Such extensive comparisons between independent theories and experiments in S19 provided us good confidence over the validity of the polarization predictions. We also note that the FAC polarization predictions are also thoroughly benchmarked in previous experiments at FLASH-EBIT (Shah et al 2015(Shah et al , 2016(Shah et al , 2018Amaro et al 2017). Here, we inferred the total flux (F tot ) from the observed flux in the experiment (F 90 ) through F tot = 4πF 90 (3 − P)/3, where P is the degree of polarization.…”
Section: Fe-l Data Measured With Flash-ebitsupporting
confidence: 55%
See 1 more Smart Citation
“…Such extensive comparisons between independent theories and experiments in S19 provided us good confidence over the validity of the polarization predictions. We also note that the FAC polarization predictions are also thoroughly benchmarked in previous experiments at FLASH-EBIT (Shah et al 2015(Shah et al , 2016(Shah et al , 2018Amaro et al 2017). Here, we inferred the total flux (F tot ) from the observed flux in the experiment (F 90 ) through F tot = 4πF 90 (3 − P)/3, where P is the degree of polarization.…”
Section: Fe-l Data Measured With Flash-ebitsupporting
confidence: 55%
“…Typical uncertainties on the measured cross section data are ∼10−25%. This can be improved for an example by implementing new measurement techniques at the EBIT, such as simultaneous X-ray observations with wideband high-resolution transition-edge sensor microcalorimeters (Durkin et al 2019;Szypryt et al 2019) and polarization measurements (Shah et al 2015(Shah et al , 2016(Shah et al , 2018 using dedicated X-ray polarimeters (Weber et al 2015;Beiersdorfer et al 2016). Further improvements can also be achieved by measuring the A&A 641, A93 (2020) electron beam and ion cloud overlap in the EBIT (Liang et al 2009;Arthanayaka et al 2020).…”
Section: Needs For Benchmarks With Laboratory Datamentioning
confidence: 99%
“…The linear polarization measurements of x-rays emitted due to dielectronic recombination into highly charged Kr ions were recently presented in [3].…”
Section: Introductionmentioning
confidence: 99%
“…The measured intensity of the emitted radiation from these ions strongly depends on the angle of observation relative to the beam axis. There have been several studies reported in the literature for the polarization of radiation emitted from ions trapped in an EBIT (Henderson et al 1990;Beiersdorfer et al 1996;Taḱacs et al 1996;Gu et al 1999;Liang et al 2009a;Hu et al 2014b;Shah et al 2015). In the present study, we measured EUV spectra using CoBIT at 90…”
Section: Experiments and Data Analysismentioning
confidence: 94%