2003
DOI: 10.1109/tns.2003.812458
|View full text |Cite
|
Sign up to set email alerts
|

Error analysis in improved motor control center method for stem thrust estimation of motor-operated valves in nuclear power plants

Abstract: An error analysis for improved motor control center (MCC) method that estimates the stem thrust of motor-operated valve (MOV) is suggested in this work. This method focuses on providing an alternative means for the periodic performance verification test with relatively lower error than the conventional MCCbased method. For evaluating the overall error of the improved MCC method, the errors are classified into two categories: the biased error and the random error. The biased error consists of the mean of the re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 7 publications
0
1
0
Order By: Relevance
“…Due to the fact that the output torque of the actuator is estimated by the active power and the accuracy of the model is limited, there is a certain discrepancy between the estimated value and the actual value. Future research is required to enhance the accuracy of torque output prediction for electric actuators [8].…”
Section: Conclusion and Further Studymentioning
confidence: 99%
“…Due to the fact that the output torque of the actuator is estimated by the active power and the accuracy of the model is limited, there is a certain discrepancy between the estimated value and the actual value. Future research is required to enhance the accuracy of torque output prediction for electric actuators [8].…”
Section: Conclusion and Further Studymentioning
confidence: 99%