2020
DOI: 10.3390/s20247122
|View full text |Cite
|
Sign up to set email alerts
|

Error Estimation of Ultra-Short Heart Rate Variability Parameters: Effect of Missing Data Caused by Motion Artifacts

Abstract: Application of ultra–short Heart Rate Variability (HRV) is desirable in order to increase the applicability of HRV features to wrist-worn wearable devices equipped with heart rate sensors that are nowadays becoming more and more popular in people’s daily life. This study is focused in particular on the the two most used HRV parameters, i.e., the standard deviation of inter-beat intervals (SDNN) and the root Mean Squared error of successive inter-beat intervals differences (rMSSD). The huge problem of extractin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
14
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(15 citation statements)
references
References 43 publications
1
14
0
Order By: Relevance
“…Another striking result is that residual errors are typically lower for longer-term (σ, lf) than for shorter-term (rmssd, hf) HRV features. This finding is consistent with [ 28 ]; it shows that high-level applications (e.g., inner states monitoring or heart event prevention) using high-frequency HRV should carefully consider the missing sample rate when running its predictions.…”
Section: Discussionsupporting
confidence: 90%
See 2 more Smart Citations
“…Another striking result is that residual errors are typically lower for longer-term (σ, lf) than for shorter-term (rmssd, hf) HRV features. This finding is consistent with [ 28 ]; it shows that high-level applications (e.g., inner states monitoring or heart event prevention) using high-frequency HRV should carefully consider the missing sample rate when running its predictions.…”
Section: Discussionsupporting
confidence: 90%
“…Another limitation of this study is that HRV features were computed without accounting for the influence of the window size (W = 60 s). Future work should also consider the combined effect of the Lack Index (L) and the window size (W) while extracting features from real-life recordings (similar work has been done with simulated data loss [ 28 ]). Bearing that in mind, whether or not pulse rate variability and HRV should be considered as distinct cardiac measures is still an open question.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In case of missing data, one needs to impute the missing data using a suitable method before modelling [5,27]. Data are missed due to various reasons, and researchers must determine the type of missing data [2,28,29].…”
Section: Discussionmentioning
confidence: 99%
“…The python hrv-analysis library (https://pypi.org/project/hrv-analysis, accesed on: 1 September 2020) is used to remove outliers and ectopic beats from signal in each long-term ECG timeseries, as showed in Rossi et al [30]. In total, 2.46 ± 4.29% of inter-beats intervals in the dataset were ectopic beats (i.e., disturbance of the cardiac rhythm frequently related to the electrical conduction system of the heart) or missing values induced by motion artefacts.…”
Section: Data Preprocessingmentioning
confidence: 99%