Erythrocyte sedimentation rate measured using microhemagglutination is not elevated in monoclonal gammopathy compared with other diseases

Abstract: We demonstrated, for the first time, that the ESR as measured by microhemagglutination is not elevated in patients with MG compared with those without. The ESR does not correlate with a particular plasma protein, showing that its measurement is multifactorial. The presence of MG is an independent factor for ΔESR.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

1
2
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 24 publications
(102 reference statements)
1
2
0
Order By: Relevance
“…[5] Measurement method for ESR in Celltac α+ (MEK 1305) [5] In the ESR measuring unit, light from an LED is emitted onto the agitated blood, and the light that passes through is continuously measured by a light-receiving element The above method comparison obtained in the present study is comparable with selected 16 similar published studies evaluating performance of various alternate/modified Westergren methods for ESR determination against reference Westergren method [Table 3]. [10][11][12][13][14][15][16][17][18][19][20][21][22][23] Intrarun precision results obtained by analyzing nine patient samples in 11 replicates yielded coefficient of variation (CV) % ranging to 0-14% which is comparable with similar studies [Table 4].…”
Section: Discussionsupporting
confidence: 58%
See 1 more Smart Citation
“…[5] Measurement method for ESR in Celltac α+ (MEK 1305) [5] In the ESR measuring unit, light from an LED is emitted onto the agitated blood, and the light that passes through is continuously measured by a light-receiving element The above method comparison obtained in the present study is comparable with selected 16 similar published studies evaluating performance of various alternate/modified Westergren methods for ESR determination against reference Westergren method [Table 3]. [10][11][12][13][14][15][16][17][18][19][20][21][22][23] Intrarun precision results obtained by analyzing nine patient samples in 11 replicates yielded coefficient of variation (CV) % ranging to 0-14% which is comparable with similar studies [Table 4].…”
Section: Discussionsupporting
confidence: 58%
“…14. Kim et al [21] 2018 published by Mahlangu and Davids, [14] Horsti et al, [17] and Schapkaitz et al [20] Celltac α+ (MEK 1305) being an automated closed system offers many advantages such as ease of performance, safety, savings on consumables, use of EDTA…”
mentioning
confidence: 99%
“…In chronic inflammatory diseases, ESR may be elevated despite a low or normal CRP owing to its immune mechanism 26‐28 . A primary screening test to predict chronic inflammatory disease would be useful as there is little opportunity to get other information for inflammation in patients with a negative CRP 29 .…”
Section: Discussionmentioning
confidence: 99%