2015
DOI: 10.1007/s13317-015-0070-x
|View full text |Cite
|
Sign up to set email alerts
|

Establishment of the upper reference limit for thyroid peroxidase autoantibodies according to the guidelines proposed by the National Academy of Clinical Biochemistry: comparison of five different automated methods

Abstract: Aim of the studyThe estimation of the upper reference limit (URL) for autoantibodies against thyroid peroxidase (TPOAbs) is a controversial issue, because of an uncertainty associated with the criteria used to correctly define the reference population. In addition, the URL of TPOAbs is method-dependent and often arbitrarily established in current laboratory practice. The aim of this study was to determine the reference limits of TPOAbs in a male sample according to the National Academy of Clinical Biochemistry… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
5
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 23 publications
2
5
0
Order By: Relevance
“…The first relevant result of the present study was the demonstration of differences between TgAb URLs claimed in the package insert (m-URL) and those obtained in the male reference sample (e-URL): with the exception of ARC and MAG method, e-URLs were lower than those proposed by the manufacturers, the difference ranging from 2.33 to 88.85%. These results were similar to those described in two previous studies dealing with the definition of TPOAb reference limits, determined by several current IMA platforms [ 30 , 31 ]. In our opinion, these discrepancies could be related to the lack of strict criteria in the selection of the subjects for the reference group.…”
Section: Discussionsupporting
confidence: 91%
See 1 more Smart Citation
“…The first relevant result of the present study was the demonstration of differences between TgAb URLs claimed in the package insert (m-URL) and those obtained in the male reference sample (e-URL): with the exception of ARC and MAG method, e-URLs were lower than those proposed by the manufacturers, the difference ranging from 2.33 to 88.85%. These results were similar to those described in two previous studies dealing with the definition of TPOAb reference limits, determined by several current IMA platforms [ 30 , 31 ]. In our opinion, these discrepancies could be related to the lack of strict criteria in the selection of the subjects for the reference group.…”
Section: Discussionsupporting
confidence: 91%
“…These results were similar to those described in two previous studies dealing with the definition of TPOAb reference limits, determined by several current IMA platforms [30, 31]. In our opinion, these discrepancies could be related to the lack of strict criteria in the selection of the subjects for the reference group.…”
Section: Discussionsupporting
confidence: 91%
“…There are a range of anti‐TPOAb assays available, with differing detection limits and thresholds for test positivity predetermined by the manufacturer. Most laboratories use one of five third‐generation commercial automated immunoassay (IMA) platforms and the cut‐off values for the upper limit of normal generally fall in the range of 10–50 iu/ml 12 . These variations are an accepted part of normal UK practice.…”
Section: Introductionmentioning
confidence: 99%
“…Currently used methods for measurement of these autoantibodies are mainly automatic immunoassays, the methods are not standardized, and assay principles are not completely similar. Thus, results obtained with one method may not be comparable with results of another method (21,22). Consequently, cut-offs are not interchangeable between the available methods emphasizing the need for method-specific cut-offs.…”
Section: Discussionmentioning
confidence: 99%