2018
DOI: 10.1088/1742-6596/1044/1/012030
|View full text |Cite
|
Sign up to set email alerts
|

Estimating the uncertainty of the specific surface area of Titanium Oxide Nanotubes calculated from nitrogen adsorption isotherms

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 6 publications
0
2
0
Order By: Relevance
“…(ii) The standard error of the three pressure transducers of the instrument is 0.13 ± 0.15% mbar of reading, which translates into a screen resolution of 1.33 × 10 –6 mbar. An analysis made independently by our group determined that the latter is indeed the parameter that most contributes to the uncertainty of the measurements . In general, the proper functioning of the instrument is regularly checked using two reference materials, namely, an aluminosilicate (part number 004-16821-00, lot number A-501-56, Brunauer–Emmett–Teller (BET) surface area = 200 ± 6 m 2 /g) and a Y zeolite (part number 004-16844-00, lot number HY-102).…”
Section: Experimental and Analytical Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…(ii) The standard error of the three pressure transducers of the instrument is 0.13 ± 0.15% mbar of reading, which translates into a screen resolution of 1.33 × 10 –6 mbar. An analysis made independently by our group determined that the latter is indeed the parameter that most contributes to the uncertainty of the measurements . In general, the proper functioning of the instrument is regularly checked using two reference materials, namely, an aluminosilicate (part number 004-16821-00, lot number A-501-56, Brunauer–Emmett–Teller (BET) surface area = 200 ± 6 m 2 /g) and a Y zeolite (part number 004-16844-00, lot number HY-102).…”
Section: Experimental and Analytical Methodsmentioning
confidence: 99%
“…An analysis made independently by our group determined that the latter is indeed the parameter that most contributes to the uncertainty of the measurements. 60 In general, the proper functioning of the instrument is regularly checked using two reference materials, namely, an aluminosilicate (part number 004-16821-00, lot number A-501-56, Brunauer−Emmett− Teller (BET) surface area = 200 ± 6 m 2 /g) and a Y zeolite (part number 004-16844-00, lot number HY-102). The reproducibility of the measurements presented in this paper was checked by testing three samples from one of the materials studied herein.…”
Section: Synthesis Of the Analyzed Materialsmentioning
confidence: 99%