2016
DOI: 10.1016/j.apradiso.2016.08.010
|View full text |Cite
|
Sign up to set email alerts
|

Estimating thickness of the inner dead-layer of n-type HPGe detector

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0
3

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(9 citation statements)
references
References 12 publications
0
6
0
3
Order By: Relevance
“…This especially applies to HPGe detectors, where the manufacturer often only provides the most basic information, e.g., crystal size and weight. X-ray imaging is a non-destructive method to obtain excellent geometry data for the crystal [28], however not the full volume of the crystal might be active volume, see Section 4.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…This especially applies to HPGe detectors, where the manufacturer often only provides the most basic information, e.g., crystal size and weight. X-ray imaging is a non-destructive method to obtain excellent geometry data for the crystal [28], however not the full volume of the crystal might be active volume, see Section 4.…”
Section: Methodsmentioning
confidence: 99%
“…We have previously used direct γ-ray emissions from the proton capture resonance of 27 Al(p,γ) 28 Si at E p = 3674.4 keV [5]. As the measurements take about a day, the intensity uncertainties are high, and angular distributions must be corrected for, we no longer perform these regularly.…”
Section: Experimental Efficiency Calibrationmentioning
confidence: 99%
See 1 more Smart Citation
“…En estos casos, las fuentes gamma de baja energía no serían adecuadas para caracterizar esta capa muerta, pues serían atenuadas antes de alcanzarla. Empleando energías altas (generalmente por encima de 500 keV) sí que sería posible, aunque el efecto de este parámetro podría verse enmascarado por otros focos de incertidumbre como el del volumen del cristal de germanio (Chuong et al 2016).…”
Section: Calibración En Eficiencia Y Caracterización Del Detector Medunclassified
“…Cada caso tiene en cuenta las capas inactivas externas óptimas logradas en el apartado anterior. (Blank et al 2015;Chuong et al 2016;García-Talavera et al 2000), obteniéndose resultados que, aunque todavía no están completamente ajustados, mejoran notablemente el modelo. En consecuencia, para alcanzar resultados aceptables para las tres geometrías, es necesario estudiar un parámetro adicional que afecte a altas energías, pero no a bajas en la medida de lo posible.…”
Section: Capa Inactiva Internaunclassified