Estimation and Analysis of VFTO at Various Locations in 132kV GIS Substation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…e expression for the suppression effect α in this article is given by (7), where U 1 and U 2 represent, respectively, the initial disturbance voltage and the disturbance voltage after adopting protective measures.…”
Section: Effect Of a Spiral Tube Damped Bus On The Vftomentioning
confidence: 99%
See 1 more Smart Citation
“…e expression for the suppression effect α in this article is given by (7), where U 1 and U 2 represent, respectively, the initial disturbance voltage and the disturbance voltage after adopting protective measures.…”
Section: Effect Of a Spiral Tube Damped Bus On The Vftomentioning
confidence: 99%
“…With multiple breakdowns and discharge of SF 6 gas, a very fast transient (VFT) of several megahertz to tens of megahertz is generated between the contacts [1][2][3]. VFT propagates in the form of a traveling wave and forms a very fast transient overvoltage (VFTO) with a short rise time and large amplitude after multiple refractions in GIS [4][5][6][7][8]. Due to the distributed capacitance between the transformer and the high-voltage bus, a VFTO will invade the secondary side of the transformer through the distributed capacitance and then enter the control chamber through the cable in the form of conduction, interfering with the secondary equipment and threatening the safe operation of the whole system [9][10][11][12][13].…”
Section: Introductionmentioning
confidence: 99%
“…Various types of transient voltages can be found in a power grid. The fastest transient voltages (i.e., very fast front overvoltage, VFFO) usually appear at a gas-insulated switchgear (GIS), which is caused by the operation of the GIS disconnectors [2][3][4]. A VFFO commonly has high frequency components of approximately 100 MHz and a rising time of several nanoseconds [5].…”
Section: Introductionmentioning
confidence: 99%