Estimation and comparison of integral dose to target and organs at risk in three-dimensional computed tomography image-based treatment planning of carcinoma uterine cervix with two high-dose-rate brachytherapy sources

Abstract: Background: Iridium-192 (192Ir) has been a widely accepted radioisotope for high-dose-rate (HDR) brachytherapy. Recently, Cobalt-60 (60Co) radioisotope with a longer half-life (5.26 years) has been gaining popularity due to economic and logistical reasons as compared with the traditional 192Ir. Aim: This study aimed to evaluate and compare the integral dose (ID) to the target and organs at risk (OARs) with two HDR brachytherapy sources in brachytherapy … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
40
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 9 publications
(42 citation statements)
references
References 23 publications
2
40
0
Order By: Relevance
“…Conclusions. The use of HDR 60 Co brachytherapy has the capacity to produce overall survival rate and disease control in patients with carcinoma of the gynaecology comparable to that reported for HDR 192 Ir brachytherapy. Currently, the toxicity and damage of the normal tissues and radiation-related second cancers are of a similar incidence to that of standard HDR 192 Ir brachytherapy.…”
mentioning
confidence: 68%
See 3 more Smart Citations
“…Conclusions. The use of HDR 60 Co brachytherapy has the capacity to produce overall survival rate and disease control in patients with carcinoma of the gynaecology comparable to that reported for HDR 192 Ir brachytherapy. Currently, the toxicity and damage of the normal tissues and radiation-related second cancers are of a similar incidence to that of standard HDR 192 Ir brachytherapy.…”
mentioning
confidence: 68%
“…Owing to this problem, HDR brachytherapy was developed but did not receive much attention until the late 1980s, for there was much concern about damage to healthy tissues that could lead to an increase in late complications. Consequently, studies concerning biological equivalence dose (BED) of HDR 60 Co to LDR were examined by many researchers. It was found that if the scheduled system for HDR is converted from single fraction treatment to a fractional one, and the time of each fraction is reduced, the damage to healthy tissues is minimized [11,12].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…The ID calculation is based on mean organ dose, mean organ density and organ volume. 24 It is defined by: where D − is the mean organ dose, V is the organ volume and ρ − is the mean organ density.…”
Section: Methodsmentioning
confidence: 99%