2017
DOI: 10.13005/ojc/330558
|View full text |Cite
|
Sign up to set email alerts
|

Estimation of Related Substances in Tigecycline by rp-hplc Method

Abstract: Estimation of related substancesby usinghigh-performance liquid chromatographic method was developed and validated for the determination of Tigecycline in the present work. Reversedphase chromatography was performed on Waters 2489 UV 2695 pump, Waters 2998 PDA 2695 pump Software Empower 2 photodiode array detector using Zorbax Eclipse plus C18 (100 mm × 4.6 mm, 1.8 µm particle size) column with eluent-A: pH 6.50 buffer: acetonitrile: DMSO (90:5:5 %v/ v/v) and eluent-B: pH 6.50 buffer: acetonitrile: DMSO (71:24… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
6
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 0 publications
2
6
1
Order By: Relevance
“…Detected system suitability parameters and tabulated parameters were satisfactory and reported theoretical plate count values, tail factor and resolution values are tabulated in (table 3). Retention time in the present study is comparable to the studies of De Silva et al [8] and Suneetha et al [9] but less than Mohan et al 2017 [12].…”
Section: System Suitability and Specificitysupporting
confidence: 87%
See 2 more Smart Citations
“…Detected system suitability parameters and tabulated parameters were satisfactory and reported theoretical plate count values, tail factor and resolution values are tabulated in (table 3). Retention time in the present study is comparable to the studies of De Silva et al [8] and Suneetha et al [9] but less than Mohan et al 2017 [12].…”
Section: System Suitability and Specificitysupporting
confidence: 87%
“…2) for simultaneous determination of Tigecycline and its related impurities (impirity 1 and imp 2). λmax is lower in the present study (231 nm) compared to the studies carried out by other researchers like De Silva et al [8] Suneetha et al [9] Hua XI et al [11] Mohan et al 2017 [12] and Zorpas et al [14] where λmax was in the range of 247 to 270 nm.…”
Section: Methods Developmentcontrasting
confidence: 70%
See 1 more Smart Citation
“…Degradation kinetic study ICH Q1A (R1) and Q1B recommendations were applied further to study the degradation of TGC under various stress conditions. 10,48 Reagents/instruments Report method (a) 33 Report method (b) 34 Report method (c) 35 The proposed method (d) . GAPI evaluation of the green character of the reported method 1 (A), reported method 2 (B), reported method 3 (C) and developed HPLC method (D).…”
Section: Discussionmentioning
confidence: 99%
“…9,10 TGC was previously determined using spectrophotometric methods, 11 fluorescence determination, [12][13][14] and liquid chromatography coupled with ultraviolet and mass spectrometry detection in human plasma [15][16][17][18][19][20][21][22][23][24][25][26] and pharmaceutical preparations. [27][28][29][30][31][32] Other methods, such as stability-indicating, [33][34][35][36][37][38][39] have also been used to determine the drug's parenteral dosage form. The bulk of these processes take significant time, are harmful to the surrounding ecosystem, and require using acetonitrile as a mobile phase.…”
Section: Introductionmentioning
confidence: 99%