“…Table 2 presents the mechanical properties of the Inconel 600 SGTs, including the lower bound J-integral value for crack growth initiation. 3.2 J-resistance curves for Incoloy 800 SGTs with circumferential cracks, Bergant et al (2012) In a previous work, Bergant et al (2012) presented a non-standardized experimental technique for J-resistance curves estimation. Specimens were fabricated from straight parts of SGTs, with one and two opposite circumferential TWCs, and were tested in pure tension at room temperature.…”