2015
DOI: 10.4067/s0718-221x2015005000014
|View full text |Cite
|
Sign up to set email alerts
|

Estudio comparativo entre fluorescencia de rayos X y reflectancia difusa de infrarrojos cercanos para la determinación de la retención en madera impregnada con arseniato de cobre cromatado

Abstract: RESUMENSe realizó un análisis comparativo de la precisión de los resultados en la determinación de la retención de óxidos de cobre, cromo y arsénico en madera impregnada con arseniato de cobre cromatado entre fluorescencia de rayos X y espectrometría de reflectancia difusa de infrarrojos cercanos. Los resultados de la calidad de las predicciones fueron comparados entre sí y con valores de retención obtenidos experimentalmente por método gravimétrico, absorción atómica y por cenizas resultantes de su calcinació… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 9 publications
0
2
0
Order By: Relevance
“…The spectral analysis of the X-rays re-emitted by fluorescence is the analytical technique that allows this equipment to obtain the characteristics of the different chemical elements in the sample. Thus, the analysis of the relative intensities for each sampling allows for concentrations of elements [26,27]. It should be noted that the equipment used to detect heavy metals, as well as essential and non-essential nutrients, detects them directly towards the plant sample due to the X-ray fluorescence it contains, and it is not necessary to prepare previous solutions to quantify some nutrients, since it is portable equipment and easy to use.…”
Section: Quantification Of Iron and Zinc In Kidney Beans (Phaseolus V...mentioning
confidence: 99%
“…The spectral analysis of the X-rays re-emitted by fluorescence is the analytical technique that allows this equipment to obtain the characteristics of the different chemical elements in the sample. Thus, the analysis of the relative intensities for each sampling allows for concentrations of elements [26,27]. It should be noted that the equipment used to detect heavy metals, as well as essential and non-essential nutrients, detects them directly towards the plant sample due to the X-ray fluorescence it contains, and it is not necessary to prepare previous solutions to quantify some nutrients, since it is portable equipment and easy to use.…”
Section: Quantification Of Iron and Zinc In Kidney Beans (Phaseolus V...mentioning
confidence: 99%
“…The impregnation efficiency is determined by two indicators, one qualitative and the other quantitative, namely, penetration and retention, respectively [26,27]. After radiata pine wood impregnations, the retention by ED XRF values for the different preservative solutions were: K1, retention of 0.96 kg/m 3 and 421 kg/m 3 density; for K2, retention of 0.86 kg/m 3 and 415 kg/m 3 density; and for M, retention of 1.01 kg/m 3 with 418 kg/m 3 density, as shown in Figure 1.…”
Section: Impregnation Process-retention Performancementioning
confidence: 99%