DOI: 10.11606/t.18.2004.tde-20122006-103114
|View full text |Cite
|
Sign up to set email alerts
|

Estudos e aplicações de barras de aço coladas, como conectores em lajes mistas de madeira e concreto para tabuleiros de pontes

Abstract: A sabedoria é vã, sem o amor. iii Dedico este trabalho à minha esposa pelo apoio e incentivo mesmo durante minhas ausências. iv AGRADECIMENTOS À minha esposa pelo incentivo e apoio durante minhas ausências Ao Professor Francisco Antonio Rocco Lahr pela orientação, incentivo, amizade e especial atenção dedicada. Ao professor Carlito Calil Júnio, pela, orientação, amizade e especial atenção dedicada. À Universidade Estadual de Maringá, ao Departamento de Engenharia Civil e aos colegas de trabalho pela oportunida… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0
20

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(27 citation statements)
references
References 2 publications
0
7
0
20
Order By: Relevance
“…Pigozzo [6] obtained the sliding modulus of the connection using a criteria similar to that recommended by the ABNT NBR 7190:1997 Brazilian Standard Code [12], (C.5 Annex), where, through the load versus deformation diagram, the secant was obtained at points corresponding to 10% and 40% of the maximum strength of the specimen. It obtained the last strength in a similar way to the recommendations given by the same Brazilian Standard Code [12] (Annex C.5; Fig, 13), that is, by secant at points 10% and 40% of the maximum strength and from a parallel line to this secant obtained the limit strength corresponding to the loading that causes the residual deformation of 0.2%.…”
Section: Methods For Sliding Modulus Determinationmentioning
confidence: 99%
See 3 more Smart Citations
“…Pigozzo [6] obtained the sliding modulus of the connection using a criteria similar to that recommended by the ABNT NBR 7190:1997 Brazilian Standard Code [12], (C.5 Annex), where, through the load versus deformation diagram, the secant was obtained at points corresponding to 10% and 40% of the maximum strength of the specimen. It obtained the last strength in a similar way to the recommendations given by the same Brazilian Standard Code [12] (Annex C.5; Fig, 13), that is, by secant at points 10% and 40% of the maximum strength and from a parallel line to this secant obtained the limit strength corresponding to the loading that causes the residual deformation of 0.2%.…”
Section: Methods For Sliding Modulus Determinationmentioning
confidence: 99%
“…Fig. 1 shows an example of load versus relative displacement diagram and curves whose angular coefficient may correspond to the sliding modulus [6].…”
Section: Literature Reviewmentioning
confidence: 99%
See 2 more Smart Citations
“…Por um lado, valores aquém do ideal não asseguram a ancoragem, por outro, valores maiores não aumentam a eficiência da ligação. Diversos aspectos podem interferir na qualidade da ancoragem de barras de aço fixadas na madeira com adesivo epóxi, dentre os quais: preenchimento completo do vazio entre a barra e a parede do furo; a presença de extrativos oleosos na madeira; formação de bolhas de ar na resina, conforme adverte PIGOZZO (2004).…”
Section: Introductionunclassified