2012
DOI: 10.1166/sl.2012.2318
|View full text |Cite
|
Sign up to set email alerts
|

Ethanol Sensor Using Zn1−xCdxO (x = 0.00 and 0.10) Nanorods by Fiber-Optic Technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…Metal oxide gas sensors based on SnO 2 , ZnO, WO 3 , etc. have attracted a great deal of attention due to their large surface to volume ratio along with stability and high crystallinity [34]. Among the numerous metal oxide semiconductors, SnO 2 , an n-type wide band-gap semiconductor, is one of the best candidates for detecting the ethanol vapors [35].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Metal oxide gas sensors based on SnO 2 , ZnO, WO 3 , etc. have attracted a great deal of attention due to their large surface to volume ratio along with stability and high crystallinity [34]. Among the numerous metal oxide semiconductors, SnO 2 , an n-type wide band-gap semiconductor, is one of the best candidates for detecting the ethanol vapors [35].…”
Section: Introductionmentioning
confidence: 99%
“…Single-mode fibers are smaller, cheaper and lighter than multimode fibers. Great number of researchers [16,17,34,36,37], took advantage of Polymethyl methacrylate (PMMA) optical fibers because those are larger, flexible and hence easier to work with. On the other hand, other researchers preferred to work with silica optical fibers [15,22].…”
Section: Introductionmentioning
confidence: 99%
“…Mn-doped Co 3 O 4 show slight increase in the band gap compared to undoped Co 3 O 4 , since the incorporation of Mn ion has tuned the band gap of metal oxide. The refractive index is related to optical band gap (E g ) of a semiconductor by using Moss relation [30]. The calculated refractive index for undoped and doped samples was 2.62, 2.26, and 2.59, 2.24 respectively, whose values are greater than that of core (1.492) and cladding (1.402).…”
Section: Uv-vis Analysismentioning
confidence: 99%
“…Due to the increase in the doping concentration, the density of the states of these dopants increases and forms a continuum of states as in the bands, hence the decrease in the band gap. 22 Refractive index and porosity of the prepared¯lms are also calculated (Table 2) respectively by the means of the following relations (Eqs. (2) and (3)) 23,24 :…”
Section: Optical Studiesmentioning
confidence: 99%