2022
DOI: 10.1016/j.jelechem.2022.116215
|View full text |Cite
|
Sign up to set email alerts
|

Evaluating the origin of the electrocatalytic activity of multiwalled carbon nanotubes towards Vitamin D3 oxidation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
11
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(11 citation statements)
references
References 29 publications
0
11
0
Order By: Relevance
“…Vibration modes of NCNT within 1600− 1995 cm −1 correspond to C�O stretching vibrations of the −COOH group attached to the CNT surface. 36 The wavenumber region within 2100−2320 cm −1 probably corresponds to hydroxyl (O−H) stretch from the strongly hydrogen-bonded −COOH group. 36 The bare CoFePBA sample exhibits fingerprint vibration at 2078 cm −1 related to C�N vibration for cyanide-coordinated compounds.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Vibration modes of NCNT within 1600− 1995 cm −1 correspond to C�O stretching vibrations of the −COOH group attached to the CNT surface. 36 The wavenumber region within 2100−2320 cm −1 probably corresponds to hydroxyl (O−H) stretch from the strongly hydrogen-bonded −COOH group. 36 The bare CoFePBA sample exhibits fingerprint vibration at 2078 cm −1 related to C�N vibration for cyanide-coordinated compounds.…”
Section: Resultsmentioning
confidence: 99%
“…36 The wavenumber region within 2100−2320 cm −1 probably corresponds to hydroxyl (O−H) stretch from the strongly hydrogen-bonded −COOH group. 36 The bare CoFePBA sample exhibits fingerprint vibration at 2078 cm −1 related to C�N vibration for cyanide-coordinated compounds. The broad hump of CoFePBA between 3300 and 3500 cm −1 corresponds to the vibration due to −OH of the coordinated H 2 O molecule inside the PBA structure.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The electro‐oxidation of vitamin D 3 was found to be unaffected by carbonaceous and metallic impurities. Good sensing performance in the 20–350 μM range and a LOD of 9.3 M was also shown by GCE modified with MWCNT [82] . Bora et al.…”
Section: Electrochemical Sensors Used To Measure Vitamin D3mentioning
confidence: 89%
“…Good sensing performance in the 20-350 μM range and a LOD of 9.3 M was also shown by GCE modified with MWCNT. [82] Bora et al designed an antibody-free, highly sensitive, carbonnanotube-based, highly responsive vitamin D 3 sensor. The sensor was delivering high performance in the concentration range of 0-10 nM, with a limit of detection of 16 pM.…”
Section: Electrochemical Sensors Based On Composite With Modified Ino...mentioning
confidence: 99%