Evaluating the PAS-SIM model using a passive air sampler calibration study for pesticides

Abstract: The main objective of this study was to evaluate the performance of a model for simulating the uptake of various pesticides on passive air samplers (PAS). From 2006-2007 a series of PAS using XAD-resin were deployed at Egbert, a rural agricultural site in southern Ontario, Canada, to measure the uptake of pesticides for time periods ranging from two months to one year. A continuous increase in sequestered amounts was observed for most pesticides, except for trifluralin and pendimethalin, which could conceivabl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
28
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
8
1

Relationship

4
5

Authors

Journals

citations
Cited by 16 publications
(30 citation statements)
references
References 34 publications
2
28
0
Order By: Relevance
“…The slope of the regression of m against C × t ( McLagan et al, 2016b;Restrepo et al, 2015) gave a very similar SR of 0.109 ± 0.009 m 3 day −1 . Because the latter method is thought to give a slightly more reliable SR (McLagan et al, 2016b;Restrepo et al, 2015), we suggest using this SR for indoor deployments of the PAS using the white Radiello and a protective shield (configuration 1). This SR is 9.9 % lower than the SR obtained in an earlier outdoor calibration study, despite the higher temperature (∼ 23 • C) indoors than outdoors (mean temperature across all deployments: 7.6 • C).…”
Section: S Mclagan Et Almentioning
confidence: 85%
“…The slope of the regression of m against C × t ( McLagan et al, 2016b;Restrepo et al, 2015) gave a very similar SR of 0.109 ± 0.009 m 3 day −1 . Because the latter method is thought to give a slightly more reliable SR (McLagan et al, 2016b;Restrepo et al, 2015), we suggest using this SR for indoor deployments of the PAS using the white Radiello and a protective shield (configuration 1). This SR is 9.9 % lower than the SR obtained in an earlier outdoor calibration study, despite the higher temperature (∼ 23 • C) indoors than outdoors (mean temperature across all deployments: 7.6 • C).…”
Section: S Mclagan Et Almentioning
confidence: 85%
“…7A). 26 This sampler has been extensively characterised in terms of the SR of different SVOCs in different climates 21,27,28,190 and with respect to the inuence of wind on the SR. 191 Experiments with different sampler congurations conrmed that the uptake rate is proportional to the surface area of the mesh cylinder 192 and both a short (10 cm) and long (20 cm) version of the sampler have been used. The deployment of multiple mesh cylinders in the same housing does not affect the SR, i.e.…”
Section: D23 Samplers Based On Polydimethyl Siloxane (Pdms)mentioning
confidence: 99%
“…8). 190 Each PAS can be treated as a single calibration experiment yielding an empirical SR e according to eqn (13). The overall SR e is then the average of the SR e obtained for each PAS.…”
Section: F the Sampling Rates Of Different Types Of Passmentioning
confidence: 99%
“…The second set of air concentrations was calculated by using a recalibrated SR obtained from the data generated in this study plus the data from the original calibration experiment (hence termed recalibrated SR). This recalibrated SR was calculated using the slope method as described by Restrepo et al (2015) and McLagan et al (2016b). Rearranging Eq.…”
Section: Calculation Of Air Concentration From the Amount Taken Up Bymentioning
confidence: 99%