1987
DOI: 10.1080/15287398709531004
|View full text |Cite
|
Sign up to set email alerts
|

Evaluating the toxicity of urban patterns of oxidant gases. I. An automated chronic gaseous animal inhalation exposure facility

Abstract: An automated animal inhalation exposure facility was designed to conduct chronic exposures of rodents to gaseous pollutants. The facility consisted of 3 walk-in chambers with modular cages to allow for exposure of up to a maximum of 480 mice or 240 adult rats. Critical parameters of operation, such as relative humidity, pollutant concentration, and temperature, were monitored continuously. Failure of the system to maintain parameters within specified limits activated the alarm system. Distribution of test gase… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

1991
1991
2019
2019

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(2 citation statements)
references
References 2 publications
0
2
0
Order By: Relevance
“…Automated, computer-operated feedback control systems have been employed for inhalation exposure studies since 1978 (Davies et al, 1987;Johnson et al, 1995;Johnson and Fechter, 1996;O'Shaughnessy and Hemenway, 1994;Moorman, 1978, 1984a,b). These early systems enabled inhalation exposure studies without operator intervention and typically achieved control to within 5% of the target concentration.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Automated, computer-operated feedback control systems have been employed for inhalation exposure studies since 1978 (Davies et al, 1987;Johnson et al, 1995;Johnson and Fechter, 1996;O'Shaughnessy and Hemenway, 1994;Moorman, 1978, 1984a,b). These early systems enabled inhalation exposure studies without operator intervention and typically achieved control to within 5% of the target concentration.…”
Section: Discussionmentioning
confidence: 99%
“…These early systems enabled inhalation exposure studies without operator intervention and typically achieved control to within 5% of the target concentration. Like our system, some systems included alarms or safety shutoff features when certain parameters were out of range as well as environmental data recording capabilities (Davies et al, 1987;Moorman, 1983, 1984). A primary difference between our system and previous automated systems is the use of modern DasyLab ® control software that requires almost no specialized engineering or programing knowledge.…”
Section: Discussionmentioning
confidence: 99%