2023
DOI: 10.1007/s13246-023-01287-8
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation and assessment of clique arrangements for the estimation of omnipolar electrograms in high density electrode arrays: an experimental animal model study

Abstract: High-density catheters combined with Orientation Independent Sensing (OIS) methods have emerged as a groundbreaking technology for cardiac substrate characterisation. In this study, we aim to assess the arrangements and constraints to reliably estimate the so-called omnipolar electrogram (oEGM). Performance was evaluated using an experimental animal model. Thirty-eight recordings from nine retrospective experiments on isolated perfused rabbit hearts with an epicardial HD multielectrode were used. We estimated … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 32 publications
0
2
0
Order By: Relevance
“…The cross-clique configuration for the omnipolar reconstruction of signals was implemented, as described in [30] and validated in an animal experimental model in [31] . From a \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{upgreek} \usepackage{mathrsfs} \setlength{\oddsidemargin}{-69pt} \begin{document} $4\times 4$\end{document} electrode grid and according to the definition of a clique, a \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{upgreek} \usepackage{mathrsfs} \setlength{\oddsidemargin}{-69pt} \begin{document} $3\times 3$\end{document} vector map is generated that displays the propagation of the wave under the catheter.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The cross-clique configuration for the omnipolar reconstruction of signals was implemented, as described in [30] and validated in an animal experimental model in [31] . From a \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{upgreek} \usepackage{mathrsfs} \setlength{\oddsidemargin}{-69pt} \begin{document} $4\times 4$\end{document} electrode grid and according to the definition of a clique, a \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{upgreek} \usepackage{mathrsfs} \setlength{\oddsidemargin}{-69pt} \begin{document} $3\times 3$\end{document} vector map is generated that displays the propagation of the wave under the catheter.…”
Section: Methodsmentioning
confidence: 99%
“…The cross-clique configuration for the omnipolar reconstruction of signals was implemented, as described in [30] and validated in an animal experimental model in [31]. From a 4 × 4 electrode grid and according to the definition of a clique, a 3 × 3 vector map is generated that displays the propagation of the wave under the catheter.…”
Section: A Creation Of Propagation Mapsmentioning
confidence: 99%