Evaluation of 2-point, 3-point, and 6-point Dixon magnetic resonance imaging with flexible echo timing for muscle fat quantification

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
61
0
2

Year Published

2018
2018
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 76 publications
(63 citation statements)
references
References 26 publications
0
61
0
2
Order By: Relevance
“…The Dixon sequence was a Gradient Echo Volumetric Interpolated Breathhold Examination 6pt Dixon prototype sequence (sequence parameter: image resolution: 0.8 × 0.8 × 3.0 mm 3 ; slices: 36, no spacing between slices; matrix size: 320 × 320; TR: 14.00 ms; TEs: 1.90, 3.73, 5.56, 7.39, 9.22, and 11.05 ms; bandwidth: 710 Hz/px; acquisition time: 1:17 min). Minimum possible TE values were selected at the given image resolution as validated previously . T 2 *‐decay was considered as a degree of freedom in the parameter extraction, and the effect on the extracted water and fat signals was eliminated using a multi‐step fitting approach .…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The Dixon sequence was a Gradient Echo Volumetric Interpolated Breathhold Examination 6pt Dixon prototype sequence (sequence parameter: image resolution: 0.8 × 0.8 × 3.0 mm 3 ; slices: 36, no spacing between slices; matrix size: 320 × 320; TR: 14.00 ms; TEs: 1.90, 3.73, 5.56, 7.39, 9.22, and 11.05 ms; bandwidth: 710 Hz/px; acquisition time: 1:17 min). Minimum possible TE values were selected at the given image resolution as validated previously . T 2 *‐decay was considered as a degree of freedom in the parameter extraction, and the effect on the extracted water and fat signals was eliminated using a multi‐step fitting approach .…”
Section: Methodsmentioning
confidence: 99%
“…Minimum possible TE values were selected at the given image resolution as validated previously. 25 T 2 *-decay was considered as a degree of freedom in the parameter extraction, and the effect on the extracted water and fat signals was eliminated using a multi-step fitting approach. 23 From the 6pt Dixon sequence, PDFF and PDWF maps were obtained.…”
Section: Magnetic Resonance Data Acquisition and Magnetic Resonance Ementioning
confidence: 99%
See 1 more Smart Citation
“…A 2‐point Dixon sequence acquires 2 different images, 1 with fat and water in phase and the other with fat and water in opposing phases. A 3‐point Dixon sequence acquires a third set of images that is typically used to correct for inhomogeneities in the magnetic field . The addition or subtraction of the resultant in‐phase or opposed‐phase images can be used to produce fat and water images, in which the intensity of individual pixels is proportional to fat or water concentration in that pixel (Fig.…”
Section: Evaluating Intramuscular Fatmentioning
confidence: 99%
“…In der Praxis führen globale und lokale Magnetfeldinhomogenitäten und ein T2*-Zerfall zu leichten Änderungen in den Werten der Resonanzfrequenzen, was durch die Akquisition weiterer Echos (sog. Mehrpunkt-Dixon-Sequenzen) kompensiert werden kann [47,48]. Mit 6 pt (6 Punkt) Dixon-Sequenzen kann am Oberschenkel routinemäßig eine Pixelgröße von 0,7 mm 2 bei einer Schichtdicke von 3 mm erreicht werden.…”
Section: D-bildgebung Mit Mrtunclassified