2010
DOI: 10.1016/j.nucmedbio.2010.04.107
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of a bolus/infusion protocol for 11C-ABP688, a PET tracer for mGluR5

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
52
1

Year Published

2013
2013
2022
2022

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 44 publications
(53 citation statements)
references
References 8 publications
0
52
1
Order By: Relevance
“…V norm is equivalent to BP ND +1=((V T -V ND )/V ND )+1). 51 mGluR5 has been successfully quantified with this approach in previous studies 46,52,53 and a preclinical study showed that the cerebellum is relatively devoid of mGluR5 and thus suitable as a reference region. 54 …”
Section: Image Acquisition and Data Analysesmentioning
confidence: 99%
See 1 more Smart Citation
“…V norm is equivalent to BP ND +1=((V T -V ND )/V ND )+1). 51 mGluR5 has been successfully quantified with this approach in previous studies 46,52,53 and a preclinical study showed that the cerebellum is relatively devoid of mGluR5 and thus suitable as a reference region. 54 …”
Section: Image Acquisition and Data Analysesmentioning
confidence: 99%
“…Before the PET acquisition, a catheter was placed in the left antecubital vein for tracer injection and a low-dose CT was conducted for attenuation correction. In order to avoid inconvenient arterial blood sampling, we relied on a previously evaluated equilibrium paradigm 46,47 based on the premise that a steady-state between tracer concentration in tissue and blood can be obtained. 48 To verify that steady-state of receptor binding was reached after 45min (frames 17 to 19), timeactivity curves were generated for high (ACC, putamen), medium (thalamus), and low receptor density regions (cerebellum) in both hemispheres for all participants.…”
Section: Image Acquisition and Data Analysesmentioning
confidence: 99%
“…11 C]ABP688 (Burger et al, 2010). Our method allowed for reliable measurement of the relative distribution volume (DVR), and reduced potential bias due to arterial blood sampling required for absolute quantification.…”
Section: Positron Emission Tomographymentioning
confidence: 99%
“…Our method allowed for reliable measurement of the relative distribution volume (DVR), and reduced potential bias due to arterial blood sampling required for absolute quantification. Equilibrium between the tracer in tissue and blood is achieved 40 min after commencing the radio-ligand infusion (Burger et al, 2010 was administered using an infusion pump (half was given as a bolus over 2 min and the other half infused over the next 58 min). Image acquisition and reconstruction were performed as described earlier (Akkus et al, 2014;Ametamey et al, 2006;Deschwanden et al, 2011;Treyer et al, 2007), using the cerebellum as the reference region.…”
Section: Positron Emission Tomographymentioning
confidence: 99%
“…Furthermore, in several studies, the cerebellum was used as a reference region for the ratio analysis in [ 11 C]ABP688 PET human brain studies using a bolus-infusion protocol. 39,40 Noise in Reference Region Data In this study, we assumed the cerebellar TAC (Supplementary Figure E3) as almost noiseless reference region input function because of its large size. However, in general, the noise level of the reference TAC may change depending on several factors such as size of the region and injection dose.…”
Section: Reference Region For [ 11 C]abp688mentioning
confidence: 99%