2009
DOI: 10.1007/s00330-009-1361-2
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of a CT triage protocol for mass casualty incidents: results from two large-scale exercises

Abstract: The purpose of this study was to evaluate the feasibility, stability, and reproducibility of a dedicated CT protocol for the triage of patients in two separate large-scale exercises that simulated a mass casualty incident (MCI). In both exercises, a bomb explosion at the local soccer stadium that had caused about 100 casualties was simulated. Seven casualties who were rated "critical" by on-site field triage were admitted to the emergency department and underwent whole-body CT. The CT workflow was simulated wi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0
3

Year Published

2013
2013
2017
2017

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 17 publications
(13 citation statements)
references
References 25 publications
0
10
0
3
Order By: Relevance
“…5,7 Particularly rare are publications concerning dedicated CT workflow in MCI handling. 6,24 In this context, a very realistic MCI simulation offered the possibility to analyse existing CT workflow with respect to process optimization, identification of bottlenecks and other limitations.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…5,7 Particularly rare are publications concerning dedicated CT workflow in MCI handling. 6,24 In this context, a very realistic MCI simulation offered the possibility to analyse existing CT workflow with respect to process optimization, identification of bottlenecks and other limitations.…”
Section: Discussionmentioning
confidence: 99%
“…But even in centres with more than one scanner, the efficiency depends on a variety of parameters such as facility factors, number of CT staff, scanning time and protocol choice as well as on image reconstruction, processing, reading, reporting and distribution time. 6,24 The aim of study was to analyse and interpret radiological MCI workflow data.…”
Section: Introductionmentioning
confidence: 99%
“…Da die typischen Extremereignisse wie Naturkatastrophen, Bombenanschläge, Flugzeug-oder Zugunglücke von einer lokalen Betrachtung aus selten auftreten,isteseine Herausforderung,auf solche Situationen gut vorbereitet zu sein [1,28]. Leider gibt es im Gegensatz zur allgemeinen Polytraumaversorgung auch wenig Richtlinien, insbesondere im Hinblick auf den Workflow im Schockraum und in der Diagnostik [16,18,21,25,30]. Aus diesen Gründen und v. a. auch zur Berücksichtigung der lokal unterschiedlichen Gegebenheiten haben sich Simulationen durchgesetzt, um die Versorgung bei einem Massenanfall von Verletzten (MANV) zu trainieren, Schwachstellen zu identifizieren und die Versorgungsabläufe entsprechend individuell zu optimieren [27,30].…”
Section: Hintergrund Und Fragestellungunclassified
“…In der Literatur sind bislang zwei dedizierte CT-Protokolle für den MANVEinsatz angegeben, wobei sich beide auf die Generation von 4-Detektorzeilen-CT-Geräte beziehen [16,18] …”
Section: Ct-protokolle Und Ct-durchsatzunclassified
“…Der Thoraxscan wird als CTA um den Hals erweitert und bis auf Höhe des Circulus Willisii akquiriert, anschließend aber getrennt rekonstruiert [6,19,26,27,35,40]. Die hohe örtliche und zeitliche Auflösung führte zur Reduktion der Bewegungsartefakte und Generierung eines Volumendatensatzes mit isotropen Voxeln, die in multiplanaren Rekonstruktionen (MPR) zur Verfügung gestellt werden können.…”
Section: Besonderheiten Bei Polytraumaunclassified