2005
DOI: 10.1089/dia.2005.7.283
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of a New Blood Glucose Monitoring System with Auto-Calibration

Abstract: These findings indicate that the Ascensia CONTOUR System, which does not require calibration by the user, is a convenient and accurate instrument with useful features for people who routinely monitor BG.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2005
2005
2016
2016

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 14 publications
(11 citation statements)
references
References 24 publications
0
11
0
Order By: Relevance
“…Variation can be due to issues such as competing blood substrates (e.g., maltose, vitamin C) (161,162), environmental issues (e.g., cold temperature, high altitude with reduced oxygen pressure), and factors related to individual patients. Reduced accuracy and precision have been observed in tests performed by patients and other lay users compared with highly trained, experienced health professionals (163). GM accuracy is just one of many factors influencing the quality of subsequent glycemic control achieved.…”
Section: What Impacts Accuracy?mentioning
confidence: 99%
“…Variation can be due to issues such as competing blood substrates (e.g., maltose, vitamin C) (161,162), environmental issues (e.g., cold temperature, high altitude with reduced oxygen pressure), and factors related to individual patients. Reduced accuracy and precision have been observed in tests performed by patients and other lay users compared with highly trained, experienced health professionals (163). GM accuracy is just one of many factors influencing the quality of subsequent glycemic control achieved.…”
Section: What Impacts Accuracy?mentioning
confidence: 99%
“…The Ascensia Contour57 by Bayer was launched a year later and used glucose dehydrogenase-flavin adenine dinucleotide and capillary fill technology requiring a meagre 0.6 μL of blood. The device produced plasma-calibrated results, with a wide analytical range of 0.6–33.3 mmol/L in just 15 s. The Ascensia Breeze II58 was released in 2007 and used 1 μL of blood but had a more innovative data management system.…”
Section: Poc Testingmentioning
confidence: 99%
“…Nine articles reported 12 studies on the performance of blood glucose meters in clinical settings [21][22][23][24][25][26][27][28][29] (Table 3).…”
Section: Performance Of Blood Glucose Meters In Clinical Settingsmentioning
confidence: 99%