1974
DOI: 10.1093/bja/46.4.253
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of a New Thin Film Tonometer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

1974
1974
2013
2013

Publication Types

Select...
7
3

Relationship

1
9

Authors

Journals

citations
Cited by 21 publications
(7 citation statements)
references
References 6 publications
0
7
0
Order By: Relevance
“… Effect of exposure to reduced O 2 tension on ATP release from erythrocytes of healthy humans. In a thin‐film tonometer [10], isolated erythrocytes (hematocrit 20%) were exposed to gas mixtures containing either 15% O 2 , 6% CO 2 , and balance nitrogen (CONTROL), or 0% O 2 , 6% CO 2 , and balance nitrogen (REDUCED O 2 ). ATP release was determined after a 30 minute equilibration with 15% O 2 and 10 minutes after exposure to 0% O 2 .…”
Section: The Erythrocyte and The Regulation Of Perfusion Distributionmentioning
confidence: 99%
“… Effect of exposure to reduced O 2 tension on ATP release from erythrocytes of healthy humans. In a thin‐film tonometer [10], isolated erythrocytes (hematocrit 20%) were exposed to gas mixtures containing either 15% O 2 , 6% CO 2 , and balance nitrogen (CONTROL), or 0% O 2 , 6% CO 2 , and balance nitrogen (REDUCED O 2 ). ATP release was determined after a 30 minute equilibration with 15% O 2 and 10 minutes after exposure to 0% O 2 .…”
Section: The Erythrocyte and The Regulation Of Perfusion Distributionmentioning
confidence: 99%
“…KCl, 2.0 CaCl2, 140.5 NaCl, 1.2 MgSO4, 11.0 glucose, 21.4 NaHCO3, and 0.5% BSA, pH 7.4), incubated at 37°C, and equilibrated with 15% O2-6% CO2-balance nitrogen in a thin-film tonometer (model 237; Instrumentation Laboratories) (6). Either 1 M of the selective Rho kinase activity inhibitor Y-27632 or its vehicle (saline) was added to the erythrocyte suspension, which was allowed to equilibrate for an additional 30 min.…”
Section: Isolation Of Erythrocytesmentioning
confidence: 99%
“…Three-ml aliquots of fresh heparinized human venous blood were equilibrated for 10 minutes with each of five gases containing oxygen concentrations varying from 4% to 95% at flow rates of 300 ml/ min, in an IL237 thin film tonometer which has recently been evaluated (Chalmers, Bird and Whitwam, 1974). The temperature of each measuring system and the tonometer was carefully maintained at 37±0.1°C.…”
Section: Determination Of the Blood Gas Factormentioning
confidence: 99%