Evaluation of a novel tripodal diglycolamide for actinide extraction: Solvent extraction and SLM transport studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

8
65
3

Year Published

2012
2012
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 48 publications
(76 citation statements)
references
References 20 publications
8
65
3
Order By: Relevance
“…As previously reported, T-DGA has limited solubility in n-dodecane alone and is fairly soluble in the diluent mixture, n-dodecane and iso-decanol (10 : 1). 14 , which is similar to that reported in several systems such as the extraction of Am 3+ and UO 2 2+ using CMPO and TODGA as the extractants, respectively. 22 Apparently, the relatively higher aqueous solubility of the butyl form of the ionic liquid was responsible for the higher metal ion extraction as will be discussed below.…”
Section: Resultssupporting
confidence: 88%
See 2 more Smart Citations
“…As previously reported, T-DGA has limited solubility in n-dodecane alone and is fairly soluble in the diluent mixture, n-dodecane and iso-decanol (10 : 1). 14 , which is similar to that reported in several systems such as the extraction of Am 3+ and UO 2 2+ using CMPO and TODGA as the extractants, respectively. 22 Apparently, the relatively higher aqueous solubility of the butyl form of the ionic liquid was responsible for the higher metal ion extraction as will be discussed below.…”
Section: Resultssupporting
confidence: 88%
“…The extractability trend for the elements is similar to that reported with the T-DGA-n-dodecane-iso-decanol system. 14 The relative extraction behaviour of Am 3+ vis-à-vis that of Sr 2+ and UO 2 2+ is interesting when compared to those observed with the analogous TODGA-n-dodecane system. 24 The separation factor values are listed in Table 3.…”
Section: Relative Extraction and Separation Behaviourmentioning
confidence: 94%
See 1 more Smart Citation
“…8 Ionic liquids, apart from having a low vapour pressure and a lower tendency for inflammability, show very large enhancements in the metal ion extraction as compared to molecular diluents. 13 Previous studies with a C-pivot tripodal diglycolamide (T-DGA) ligand have indicated very high D Am values at 3 M HNO 3 (usual feed acid concentration for high level radioactive wastes) in molecular diluents, 14 15 In the present study, the extraction/separation behaviour of a new type of N-pivot DGA ligand, DGA-TREN ( Fig. 10 In general, though selectivities in ionic liquids are found to improve manifold as compared to molecular diluents for the Am 3+ -UO 2 2+ (or Am 3+ -Pu 4+ ) pair in DGA extractants, similar observations were not made for the Am 3+ -Eu 3+ pair.…”
Section: Introductionmentioning
confidence: 99%
“…Studies on membrane separation of uranium have included systems based on bulk liquid membranes, emulsion liquid membranes and supported liquid membranes [18][19][20][21][22][23]. Whilst the current techniques of separating uranium are considered costeffective and relatively efficient, many workers have sought to find safer methods for separation where chemical inventories are reduced.…”
Section: Introductionmentioning
confidence: 99%