Evaluation of a silicon photomultiplier PET insert for simultaneous PET and MR imaging

Abstract: The developed MR-compatible PET insert is designed for insertion into a narrow-bore magnetic resonance imaging scanner, and it provides excellent imaging performance for PET/MR preclinical studies.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
57
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
3
3

Relationship

2
4

Authors

Journals

citations
Cited by 51 publications
(61 citation statements)
references
References 37 publications
4
57
0
Order By: Relevance
“…The developed SiPM PET system achieves submillimeter spatial resolution in the center of the FOV (0.7 mm in-plane using iterative image reconstruction of a point source in air) desired for rodent brain imaging and high peak system sensitivity (.3%) desired for dynamic PET studies with short-lived radiotracers and short time frames (22). Our new PET system neither significantly degrades the MRI information nor is affected by MRI acquisition.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…The developed SiPM PET system achieves submillimeter spatial resolution in the center of the FOV (0.7 mm in-plane using iterative image reconstruction of a point source in air) desired for rodent brain imaging and high peak system sensitivity (.3%) desired for dynamic PET studies with short-lived radiotracers and short time frames (22). Our new PET system neither significantly degrades the MRI information nor is affected by MRI acquisition.…”
Section: Discussionmentioning
confidence: 99%
“…The PET insert yields superb performance for small-animal imaging (22). The radial/tangential/axial resolutions estimated from reconstructed point source images using ordered-subset expectation maximization were 0.75/0.68/1.05 mm at the center of the FOV and 1.46/0.71/ 1.22 mm at the 14-mm radial off-center.…”
Section: Mr-compatible Sipm Pet Systemmentioning
confidence: 97%
See 1 more Smart Citation
“…SiPM is widely believed to be the future photodetector for PET scanners . Clinic whole body PET scanners and preclinical PET scanners were already built with SiPM based detectors . But so far only a few studies were done on dual‐ended readout PET detector development with SiPMs and all of those studies used crystal size of 1.5 mm or bigger .…”
Section: Introductionmentioning
confidence: 99%
“…25,26 Clinic whole body PET scanners 27 and preclinical PET scanners were already built with SiPM based detectors. [28][29][30] But so far only a few studies were done on dual-ended readout PET detector development with SiPMs and all of those studies used crystal size of 1.5 mm or bigger. 21,[31][32][33] The focus of this work is to develop high resolution, high efficient and high DOI resolution small animal PET detectors using dual-ended readout of pixelated LYSO arrays optically coupled with SiPM arrays.…”
Section: Introductionmentioning
confidence: 99%