2008
DOI: 10.1111/j.1532-950x.2008.00371.x
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of a Thoracoscopic Technique Using Ligating Loops to Obtain Large Lung Biopsies in Standing Healthy and Heaves‐Affected Horses

Abstract: Using laparoscopic pre-tied ligating loop for thoracoscopically-assisted lung biopsy can be considered in horses with normal and impaired lung function but alternative instrumentation and access to intranasal oxygen must be available to the surgeon in case of complications.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
41
1
4

Year Published

2012
2012
2024
2024

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 30 publications
(46 citation statements)
references
References 30 publications
0
41
1
4
Order By: Relevance
“…Testing was performed when the horses had been pastured for 3 mo (Baseline) to induce clinical remission of the disease, and after a natural 30-day antigenic challenge (Antigen challenge) consisting of stabling and hay feeding. Thoracoscopic guided lung biopsies specimens were obtained from the 12th intercostal space as previously described (31). Horses with heaves, but not controls, developed airway neutrophilia (BALF neutrophils; means Ϯ SE 32 Ϯ 22.6% in horses with heaves, 3.1 Ϯ 2.5% in control horses) and obstruction [pulmonary resistance (RL) 4.86 Ϯ 3.52 cmH2O·l Ϫ1 ·s Ϫ1 in horses with heaves; RL 0.51 Ϯ 0.23 cmH2O·l Ϫ1 ·s Ϫ1 in control horses] with stabling and hay feeding.…”
Section: Methodsmentioning
confidence: 99%
“…Testing was performed when the horses had been pastured for 3 mo (Baseline) to induce clinical remission of the disease, and after a natural 30-day antigenic challenge (Antigen challenge) consisting of stabling and hay feeding. Thoracoscopic guided lung biopsies specimens were obtained from the 12th intercostal space as previously described (31). Horses with heaves, but not controls, developed airway neutrophilia (BALF neutrophils; means Ϯ SE 32 Ϯ 22.6% in horses with heaves, 3.1 Ϯ 2.5% in control horses) and obstruction [pulmonary resistance (RL) 4.86 Ϯ 3.52 cmH2O·l Ϫ1 ·s Ϫ1 in horses with heaves; RL 0.51 Ϯ 0.23 cmH2O·l Ϫ1 ·s Ϫ1 in control horses] with stabling and hay feeding.…”
Section: Methodsmentioning
confidence: 99%
“…Den Autoren dieser Arbeit war bisher keine vergleichbare Studie bekannt, in der das exspiratorische Atemzugvolumen, das exspiratorische Atemminutenvolumen und der endexspiratorische Kohlendioxidgehalt am stehenden thorakoskopierten Pferd gemessen wurden. Die wenigen Arbeiten hierzu beschränken sich lediglich auf Blutgasanalysen (Vachon und Fischer 1998, Relave et al 2008Boy und Sweeney 2000, Peroni et al 2000. Die Blutgasanalyse liefert zwar wertvolle Informationen über die momentane respiratorische Effektivität eines Patienten, erlaubt aber keine direkte Beurteilung der pulmonalen Funktion und hängt dazu noch von weiteren Faktoren wie zum Beispiel von der peripherer Organperfusion und der Gasaustauschkapazität ab.…”
Section: Diskussionunclassified
“…Die transiente Hypoxämie konnte durch Wiederherstellung des Unterdrucks im Pleuraspalt und folgender Reexpansion der Lunge schnell behoben werden. Zur Verbesserung der Sauerstoffversorgung wurde von anderen Autoren eine intranasale Supplementierung mit Sauerstoff von mindestens 10l/min während des Eingriffes empfohlen (Relave et al 2008, Wilson et al 2006 …”
Section: Exspiratorisches Atemzugvolumenunclassified
“…Bisher liegen nur wenige Angaben darüber vor, welche Auswirkungen der Pneumothorax im Rahmen einer Thorakoskopie auf die Herzkreislaufund Atemfunktionen beim Pferd besitzt (Peroni et al 2000, Relave et al 2008 Beeinflussung der ersten Messung weitgehend auf die nachfolgende auszuschließen, betrug der Abstand zwischen den beiden Thorakoskopien mindestens sieben Tage.…”
Section: Zusammenfassungunclassified