Evaluation of an automatic MR-based gold fiducial marker localisation method for MR-only prostate radiotherapy

Abstract: An MR-only radiotherapy planning (RTP) workflow would reduce the cost, radiation exposure and uncertainties introduced by CT-MRI registrations. In the case of prostate treatment, one of the remaining challenges currently holding back the implementation of an RTP workflow is the MR-based localisation of intraprostatic gold fiducial markers (FMs), which is crucial for accurate patient positioning. Currently, MR-based FM localisation is clinically performed manually. This is sub-optimal, as manual interaction inc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

6
53
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 25 publications
(59 citation statements)
references
References 67 publications
6
53
0
Order By: Relevance
“…There have been a number of studies investigating dedicated MRI sequences for fiducial detection . Both balanced steady‐state free precession sequences and sequences based on spoiled gradient‐echoes have been employed in 2D and 3D acquisitions, relying on T2*‐related signal loss to create a detectable signal void in the vicinity of the fiducials. The averaging of consecutive echoes in multi‐echo recalled sequences, such as the one used here is an attractive mechanism to increase the signal‐to‐noise ratio.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…There have been a number of studies investigating dedicated MRI sequences for fiducial detection . Both balanced steady‐state free precession sequences and sequences based on spoiled gradient‐echoes have been employed in 2D and 3D acquisitions, relying on T2*‐related signal loss to create a detectable signal void in the vicinity of the fiducials. The averaging of consecutive echoes in multi‐echo recalled sequences, such as the one used here is an attractive mechanism to increase the signal‐to‐noise ratio.…”
Section: Discussionmentioning
confidence: 99%
“…The accuracy of fiducial detection is paramount and can be either manual or automatic . However, ultimately, this must be performed automatically, especially if intrafractional imaging is to be used.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…In T2‐weighted (T2w) MRI‐images, GFM, calcifications and bleeding will have similar signal behavior and be depicted as signal voids . This makes differentiating between these objects a challenging task using solely MRI‐images in an MRI‐only radiotherapy workflow.…”
Section: Introductionmentioning
confidence: 99%