2010
DOI: 10.1016/j.jaerosci.2010.09.002
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of bioaerosol sampling techniques for Legionella pneumophila coupled with culture assay and quantitative PCR

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
20
1

Year Published

2012
2012
2020
2020

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 25 publications
(23 citation statements)
references
References 38 publications
2
20
1
Order By: Relevance
“…The parameter CS represents the colony survival rate of E. faecalis aerosols on each agar medium; isolates with higher CS values correspond to species that are more resistant to the stress of air sampling. The following levels of resistance to stress from impaction and filtration have previously been reported ( (Li and Lin 1999a,b;Li et al 2003;Tseng and Li 2005;Chang et al, 2010;Hsiao et al 2012). The CS of gram-positive E. faecalis in the present study (CS = 0.6-1.2) was much higher than those reported for S. aureus and E. coli.…”
Section: Chamber Studysupporting
confidence: 56%
“…The parameter CS represents the colony survival rate of E. faecalis aerosols on each agar medium; isolates with higher CS values correspond to species that are more resistant to the stress of air sampling. The following levels of resistance to stress from impaction and filtration have previously been reported ( (Li and Lin 1999a,b;Li et al 2003;Tseng and Li 2005;Chang et al, 2010;Hsiao et al 2012). The CS of gram-positive E. faecalis in the present study (CS = 0.6-1.2) was much higher than those reported for S. aureus and E. coli.…”
Section: Chamber Studysupporting
confidence: 56%
“…Literature indicates the TM may help in reducing osmotic shock to bacteria and improving cell suspension in liquid (Chang et al, 2010). The PBS was the DW containing 0.82% NaCl, 0.02% KCl, 0.115% Na 2 HPO 4 , and 0.02% KH 2 PO 4 .…”
Section: Collection Fluidmentioning
confidence: 99%
“…The well-characterized swirling liquid impinger (BioSampler) was used as a reference air sampler in this study (Willeke et al 1998;Lin et al , 2000Hermann et al 2006;Rule et al 2007;Fabian et al 2009;Van Droogenbroeck et al 2009;Chang et al 2010;Kesavan et al 2010b;Chang and Chou 2011;Kesavan et al 2011). Compared to the BioSampler, the available performance data for the rest of the involved air samplers were more limited; gelatin filters (Li 1999;Lin and Li 1999;Tseng and Li 2005;Burton et al 2007;Fabian et al 2009;Van Droogenbroeck et al 2009;Chang and Chou 2011;Estill et al 2011;Zhao et al 2011), Coriolis FR (or Coriolis μ and δ) (Carvalho et al 2008;Gómez-Domenech et al 2010;Ahmed et al 2013), XMX-CV (or XMX/2L-MIL and XMX/2A) (Cooper 2010;Black 2011;Kesavan et al 2011;Black and Cooper 2012;Enderby 2012), BioCapture 650 (Kesavan et al 2011;Enderby 2012), OMNI-3000 (Kesavan et al 2011;Zhao et al 2011), SASS 2300(or SASS 2000 (Kesavan and Stuebing 2009;Kesavan et al 2011), andSASS 3100 (Kesavan et al 2010b).…”
Section: Introductionmentioning
confidence: 99%