Evaluation of Building Displacement Induced By EPB Tunneling Through GPS-GNSS Monitoring System and Back Analysis Technique (Tabriz Subway Twin Tunnels)

Abstract: One of the main aspects of tunneling in urban areas is controlling the amount of settlement that might cause some damage to the structures and infrastructures. In this paper, the novel displacement monitoring system called Global Positioning System - Global Navigation Satellite System (GPS-GNSS) has been applied to monitor the building displacement .One of the most important features of this approach is that this system provides three dimensional displacement behavior of the building. Besides, in order to fulf… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 16 publications
0
3
0
Order By: Relevance
“…Also the line is routed through the downtown of a major metropolitan area and beneath the crowded city streets and adjacent to high raised and important buildings. Previous researches see [59,60] Primarily geotechnical study of 2 nd line is performed by drilling 53 boreholes and 17 wells. Also to study the complementary geotechnical research of this line, 92 boreholes and 3 wells have been drilled.…”
Section: Studied Areamentioning
confidence: 99%
“…Also the line is routed through the downtown of a major metropolitan area and beneath the crowded city streets and adjacent to high raised and important buildings. Previous researches see [59,60] Primarily geotechnical study of 2 nd line is performed by drilling 53 boreholes and 17 wells. Also to study the complementary geotechnical research of this line, 92 boreholes and 3 wells have been drilled.…”
Section: Studied Areamentioning
confidence: 99%
“…Discrepancy between measured and computed value of pore water pressure is expressed as the error function [15]:…”
Section: Comparison Between Normal and Back Analysismentioning
confidence: 99%
“…Due to the advantages of the real-time 3D absolute displacements of monitoring, continuous autonomous operation, and reliable performance in various weather and visibility conditions, GNSS sensors have proven to be effective for deformation monitoring in structures such as tall buildings, dams, and bridges [1][2][3][4]. Compared to traditional monitoring methods, GNSS overcome many limitations, as they can easily identify lowfrequency structural vibration responses.…”
Section: Introductionmentioning
confidence: 99%