Abstract: Summary This article discusses evaluation of dynamic contribution of wind turbine unit of doubly fed induction generators (DFIGs) type and capacitive energy storage (CES) in frequency regulation services in 2‐area interconnected power system, having diverse thermal‐hydro‐gas (T‐H‐G) generating units in deregulated power environment. To obtain optimal dynamic responses of area's frequency oscillations following a small load perturbation, CES/DFIG units have been included in both control areas in coordination wi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
27
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 32 publications
(28 citation statements)
references
References 37 publications
0
27
0
Order By: Relevance
“…Any sudden load change or generation loss in any area can induce a transient frequency change in the other nearby control areas as well. Therefore, effective control should be required to retain the power generation‐consumption balance and scheduled power interchange between the control areas . Figure shows a linearized model of a two‐area interconnected power system having different generating units (hydro, thermal, gas, and wind) working in the deregulated electricity market scenario .…”
Section: System Investigatedmentioning
confidence: 99%
See 3 more Smart Citations
“…Any sudden load change or generation loss in any area can induce a transient frequency change in the other nearby control areas as well. Therefore, effective control should be required to retain the power generation‐consumption balance and scheduled power interchange between the control areas . Figure shows a linearized model of a two‐area interconnected power system having different generating units (hydro, thermal, gas, and wind) working in the deregulated electricity market scenario .…”
Section: System Investigatedmentioning
confidence: 99%
“…The number of GENCOs and the number of DISCOs are represented by the rows and columns of the DPM matrix, respectively . The DPM for the system under study consisting of different contract participation factors (CPFs) is given in (1) as shown below: leftDPM=centerCPF11CPF12CPF13CPF14CPF21CPF22CPF23CPF24CPF31CPF32CPF330.5emCPF340.5emCPF41CPF51CPF61CPF42CPF52CPF62CPF43CPF53CPF63CPF44CPF54CPF64G1G2leftG3leftG4G5G6AREA2AREA1GENCOSD14.36emD2D34.36emD4newline13.5emDISCOnormalS …”
Section: System Investigatedmentioning
confidence: 99%
See 2 more Smart Citations
“…But the dynamic response has much oscillation, and to reduce the frequency oscillation has become a new challenge. Battery energy storage and FACT devices have shown the promising result to damp oscillation . AC/DC links in each area has been used to improve oscillation .…”
Section: Introductionmentioning