2017
DOI: 10.1016/j.ijepes.2017.06.009
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of controlled energization of shunt reactors for minimizing asymmetric DC component of charging current with circuit breaker having pre-insertion resistors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 12 publications
0
7
0
Order By: Relevance
“…The PIR-CB contains two switches (namely interrupter and PIR switch) with PIR per phase. The details of various configurations of PIR, their behaviours, and the advantages of different configurations are reported in literatures [24,25]. In practise, the hybrid combination of PIR-CB with controlled switching device can be implemented without any additional efforts.…”
Section: Effect Of Pir-cb During Energisation Of An Unloaded Power Trmentioning
confidence: 99%
See 1 more Smart Citation
“…The PIR-CB contains two switches (namely interrupter and PIR switch) with PIR per phase. The details of various configurations of PIR, their behaviours, and the advantages of different configurations are reported in literatures [24,25]. In practise, the hybrid combination of PIR-CB with controlled switching device can be implemented without any additional efforts.…”
Section: Effect Of Pir-cb During Energisation Of An Unloaded Power Trmentioning
confidence: 99%
“…Therefore, the electrical insertion time (EIT) and MIT of PIR-CB are also different from each other. It is to be noted that the time laps between the electrical closing of interrupter and PIR switch are known as EIT, whereas the time laps between the mechanical closing of an interrupter and PIR switch is defined as MIT [23][24][25].…”
Section: Effect Of Pir-cb During Energisation Of An Unloaded Power Trmentioning
confidence: 99%
“…This meticulous orchestration ensures that transient effects are minimized, safeguarding the integrity and stability of the system. [6,7]. When the converter side breaker is closed, the current drawn from the secondary side of converter transformer is very high, due to the charging of the capacitors of the SMs of the FB-MMC.…”
Section: Introductionmentioning
confidence: 99%
“…They also investigated the coupling relationship between several key factors affecting switching transients; closing target angle, resistor insertion time, and resistor size are all key factors in switching transients for both single-group and back-to-back switches. Bhatt et al [20] minimize the level of asymmetric DC component of charging current during energization of a shunt reactor using a Controlled Switching Device (CSD) with a PIR-Circuit Breaker, by optimizing the insertion instant, value, and Electrical Insertion Time of PIR. Eliyan et al [21] used the PIR of a conventional circuit breaker with three other link technologies to reduce operational overvoltage in wind farms.…”
Section: Introductionmentioning
confidence: 99%
“…Bhatt et al. [20] minimize the level of asymmetric DC component of charging current during energization of a shunt reactor using a Controlled Switching Device (CSD) with a PIR‐Circuit Breaker, by optimizing the insertion instant, value, and Electrical Insertion Time of PIR. Eliyan et al.…”
Section: Introductionmentioning