2021
DOI: 10.3390/app11167694
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Cyclic Fatigue and Bending Resistance of Coronal Preflaring NiTi File Manufactured with Different Heat Treatments

Abstract: Coronal preflaring NiTi files should possess proper hardness, resistance to fracture and flexibility. This study compared the bending resistance and cyclic fatigue resistance of three orifice preflaring NiTi files. HyFlex EDM Orifice opener (#25/12), HyFlex CM (#25/08) and One Flare (#25/09) were tested (n = 46/instrument). Bending resistance was assessed with the stress when perpendicular displacement was applied to a 3 mm point from the file tip, and was performed at either room temperature (RT, n = 10) or b… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
2
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 35 publications
0
2
0
1
Order By: Relevance
“…К данным сплавам принадлежат файлы линейки XP-endo (FKG Dentire, Switzerland). Специфическая заданная форма и высокая гибкость позволяют этим инструментам сжиматься и расширяться внутри канала, обрабатывая участки, которых другие инструменты не могут достичь [9].…”
Section: Introductionunclassified
“…К данным сплавам принадлежат файлы линейки XP-endo (FKG Dentire, Switzerland). Специфическая заданная форма и высокая гибкость позволяют этим инструментам сжиматься и расширяться внутри канала, обрабатывая участки, которых другие инструменты не могут достичь [9].…”
Section: Introductionunclassified
“…Because of the reorientation capacity of the twinned phase structure, martensite has a superior cyclic fatigue resistance compared with austenite. And have a lower modulus of elasticity (30)(31)(32)(33)(34)(35)(36)(37)(38)(39)(40) than austenite (80-90 GPa). 5 So many manufacturers depend on the change of transformation temperatures (Ms, Mf, As, Af) of the utilized NiTi alloy, to alter the composition of phase to obtain a NiTi alloy with new properties.…”
Section: Introductionmentioning
confidence: 99%
“…24 In accordance with previous findings, several studies proved that Hyflex EDM exhibits a significantly increased cyclic fatigue resistance compared with Hyflex CM, M-Wire and conventional Ni-Ti instruments. 24,29,30,31,32,33,34 The Hyflex designed and marketed to shape and prepare root canals using a single-file technique in continuous rotation. 35 Hyflex EDM files have a tip size of 25, with a constant taper 0.08 in the apical 4mm of the instruments.…”
Section: Introductionmentioning
confidence: 99%