Evaluation of emissions and exposures at workplaces using desktop 3-dimensional printers

Abstract: There is a paucity of data on additive manufacturing process emissions and personal exposures in real-world workplaces. Hence, we evaluated atmospheres in four workplaces utilizing desktop “3-dimensional” (3-d) printers [fused filament fabrication (FFF) and sheer] for production, prototyping, or research. Airborne particle diameter and number concentration and total volatile organic compound concentrations were measured using real-time instruments. Airborne particles and volatile organic compounds were collect… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

3
46
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 52 publications
(49 citation statements)
references
References 28 publications
3
46
0
Order By: Relevance
“…The types of VOCs and their concentrations varied among facilities. All personal VOC levels were well below applicable National Institute for Occupational Safety and Health (NIOSH) Recommended Exposure Limit (REL) values [83].…”
Section: Assessment and Characterisation Of The Emissionsmentioning
confidence: 88%
See 2 more Smart Citations
“…The types of VOCs and their concentrations varied among facilities. All personal VOC levels were well below applicable National Institute for Occupational Safety and Health (NIOSH) Recommended Exposure Limit (REL) values [83].…”
Section: Assessment and Characterisation Of The Emissionsmentioning
confidence: 88%
“…Stefaniak et al [83] evaluated atmospheres in four workplaces utilizing 22 FFF desktop 3D printers. Airborne particle diameter, number concentration and total volatile organic compound concentrations were measured using real-time instruments.…”
Section: Assessment and Characterisation Of The Emissionsmentioning
confidence: 99%
See 1 more Smart Citation
“…Particle emission rates ranged from 10 9 to 10 11 particles/min and organic chemical concentration in workplace air displayed great variation.Influencing parameters were, among others, instrument design, filament material and build settings.The types of VOCs and their concentrations varied among facilities. All personal VOC levels were well below applicable National Institute for Occupational Safety and Health (NIOSH) Recommended Exposure Limit (REL) values[83].…”
mentioning
confidence: 87%
“…The authors note that the type of emissions may be connected not only to thermal degradation of the polymer, but to the decomposition of chemical additives (dyes, fillers plasticizers, flame retardant)[80].Stefaniak et. al [83]. evaluated atmospheres in four workplaces utilizing 22 FFF desktop 3D printers.…”