2011
DOI: 10.1128/jcm.00335-11
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Four Commercial Real-Time PCR Assays for Detection of Bordetella spp. in Nasopharyngeal Aspirates

Abstract: We evaluated the performances of 4 commercial real-time PCR kits for Bordetella pertussis IS481 sequence detection in nasopharyngeal aspirates by comparison with an in-house real-time PCR assay. Among them, the Simplexa Bordetella pertussis/parapertussis assay (Focus Diagnostics), the SmartCycler Bordetella pertussis/ parapertussis assay (Cepheid), and Bordetella R-gene (Argene) present sensitivities over 90%. One kit proved unsuitable for routine clinical use.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
15
0
3

Year Published

2012
2012
2019
2019

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 33 publications
(18 citation statements)
references
References 13 publications
0
15
0
3
Order By: Relevance
“…Several commercial assays are available for detection of B. pertussis and B. parapertussis (135)(136)(137)(138). Most assays target IS481 and IS1001 in a real-time multiplex PCR format; examples are the assays available from Elitech, Eragen, and Focus Diagnostics (135), Cepheid (136), and Diagenode (137).…”
Section: Pcr Assaysmentioning
confidence: 99%
See 1 more Smart Citation
“…Several commercial assays are available for detection of B. pertussis and B. parapertussis (135)(136)(137)(138). Most assays target IS481 and IS1001 in a real-time multiplex PCR format; examples are the assays available from Elitech, Eragen, and Focus Diagnostics (135), Cepheid (136), and Diagenode (137).…”
Section: Pcr Assaysmentioning
confidence: 99%
“…All assays contain an internal control, and some assays also use an extraction control (Focus, Argene). Comparisons of these assays were performed with in-house real-time PCR assays for detection of B. pertussis (135)(136)(137). The sensitivities of the commercial assays were found to range from 96% to 98% compared to the inhouse assays.…”
Section: Pcr Assaysmentioning
confidence: 99%
“…Susceptibility to ampicillin (10 µg), erythromycin (15 µg Detection of IS481was carried out using an inhouse reference real-time PCR method as previously described [10] until August 2012. After that time, validated commercial kits were used for the detection of both IS481 and IS1001, i.e., Simplexa Bordetella pertussis/parapertussis (FOCUS Diagnostics Cypress, California, USA) until March 2013 and Bordetella pertussis/parapertussis triplex (Bio-Evolution, Brysur-Marne, France) until September 2013, following the manufacturer's protocols [11]. B. pertussis ATCC 9797 DNA was used as positive control for the in-house realtime PCR.…”
Section: Identification Serotyping and Susceptibility Testing Of Ismentioning
confidence: 99%
“…This will be discussed in more detail later in this minireview. IS1001 is found in B. parapertussis at approximately 20 copies per genome (35) and has been used in multiplex PCR with IS481 to detect and differentiate B. pertussis and B. parapertussis (14,16,29,31). IS1001 is also present in isolates of B. bronchiseptica (4 of 73 human-derived isolates tested by Tatti et al [31] and 26 of 38 animal-derived isolates tested by van der Zee et al [34]) at 1 to 7 copies per genome (34 (Table 2).…”
Section: Gene Targets In Bordetella Naatsmentioning