2011
DOI: 10.1016/j.acra.2011.02.011
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of Hardware-related Geometrical Distortion in Structural MRI at 7 Tesla for Image-guided Applications in Neurosurgery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

4
44
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 38 publications
(48 citation statements)
references
References 36 publications
4
44
0
Order By: Relevance
“…For coregistration, high-resolution T1-weighted images from 7T MRI and from 3T MRI were skull-stripped using CBS Tools (http://www.cbs.mpg.de/institute/ software/cbs-hrt; Lucas et al, 2010;Bazin et al, 2012;Landman et al, 2013), and the stripped 7T structural image was coregistered onto the stripped 3T structural image and then once more onto the SPM8 T1 template image (Montreal Neurological Institute). These coregistered 7T structural images were obtained to confirm correct registration between the two experiment sessions and the absence of spatial distortion, which is known to increase with higher magnetic field strength (Dammann et al, 2011). The fMRI images were normalized to the standard SPM8 T1 template image and smoothed with an isotropic 3 mm full-width halfmaximum (FWHM) Gaussian kernel.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…For coregistration, high-resolution T1-weighted images from 7T MRI and from 3T MRI were skull-stripped using CBS Tools (http://www.cbs.mpg.de/institute/ software/cbs-hrt; Lucas et al, 2010;Bazin et al, 2012;Landman et al, 2013), and the stripped 7T structural image was coregistered onto the stripped 3T structural image and then once more onto the SPM8 T1 template image (Montreal Neurological Institute). These coregistered 7T structural images were obtained to confirm correct registration between the two experiment sessions and the absence of spatial distortion, which is known to increase with higher magnetic field strength (Dammann et al, 2011). The fMRI images were normalized to the standard SPM8 T1 template image and smoothed with an isotropic 3 mm full-width halfmaximum (FWHM) Gaussian kernel.…”
Section: Methodsmentioning
confidence: 99%
“…Among the available theories, we suggest that the concept of cross-temporal contingencies (Koechlin and Summerfield, 2008) was most suitable for generating the levels of cognitive hierarchies in both L2 and NL in the present study. (Desmond et al, 1998). In neuropsychological studies, patients with CN lesions were impaired in a controlled processing where an additional top-down process had to be intervened (Copland et al, 2000).…”
Section: The Pfcmentioning
confidence: 99%
“…However, MR images at 3 or 7 T may be altered by higher spatial distortions. 3 Thus, stereotactic targeting of the STN in patients with PD by direct visualization with ultra-high-field MRI with 3-or 7-T MR units may not be optimal. Furthermore, even at 7 T, the STN of NHPs cannot be delineated without a special contrast medium, such as the ultrasmall superparamagnetic iron oxide.…”
mentioning
confidence: 99%
“…3,25,31 Targeting of the STN is currently done stereotactically, which implies that the STN can be located from outside of the skull. Help from an anatomical atlas may be limited because of intersubject variations of such a small and deep brain structure.…”
mentioning
confidence: 99%
“…However, it reduces the total error of the procedure and thus promotes a more comprehensive understanding of therapeutic outcomes. In that regard, 2 recent studies 29,30 investigated possible issues for neurosurgical targeting due to higher geometric distortions at 7T. Without dissent, they reported relatively small distortions in the central brain regions and concluded that targeting is feasible with 7T imaging.…”
Section: Discussionmentioning
confidence: 99%