2009
DOI: 10.1002/cyto.a.20747
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of intensity‐based ratiometric FRET in image cytometry—Approaches and a software solution

Abstract: The intensity-based ratiometric FRET (fluorescence resonance energy transfer) method is a powerful technique for following molecular interactions in living cells. Since it is not based on irreversibly destroying the donor or the acceptor fluorophores, the time course of changes in FRET efficiency values can be monitored by this method. ImageJ, a sophisticated software tool for many types of image processing allows users to extend it with programs for various purposes. Implementing intensity-based ratiometric F… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
69
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 61 publications
(70 citation statements)
references
References 25 publications
1
69
0
Order By: Relevance
“…In the present paper, on the other hand, for the first time in the literature, the lesions were measured through specific software [6][7][8][9][10][11][12] , confirming that the corticosteroids reduce the lesion area in the infants and pubescents. These results can not be attributed to individual variations or to discrepancies in the ablation procedure.…”
Section: Major Findingssupporting
confidence: 63%
See 1 more Smart Citation
“…In the present paper, on the other hand, for the first time in the literature, the lesions were measured through specific software [6][7][8][9][10][11][12] , confirming that the corticosteroids reduce the lesion area in the infants and pubescents. These results can not be attributed to individual variations or to discrepancies in the ablation procedure.…”
Section: Major Findingssupporting
confidence: 63%
“…For the planimetric evaluation of the lesions, ImageJ™ 6,7 software was used -broadly disseminated in cytometry 8 and other planimetric studies [9][10][11][12] -which automatically calculates the lesion area ( Figure 1) with good precision and measurement converter to any desired unit by the operator. The measurement is manual, using the computer mouse that, contouring the edges of the lesion, generates automatically the measurement result.…”
Section: Quantitative Analysismentioning
confidence: 99%
“…The measured intensities (I 1-3 ) are described by the following set of equations and references (2,5,6):…”
Section: Introductionmentioning
confidence: 99%
“…Solving the above equation set for the FRET efficiency (E) yields different results depending on which overspill constants can be neglected and on the form of the equation describing I 3 . The solutions have been published elsewhere (2,(5)(6)(7)(8).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation