2017
DOI: 10.1016/j.ejpe.2016.08.005
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of kaolin clay as natural material for transformer oil treatment to reduce the impact of ageing on copper strip

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
1
0
2

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 5 publications
0
1
0
2
Order By: Relevance
“…Kaolin digunakan sebagai bahan baku di berbagai industri. Penggunaan kaolin yang terutama adalah di industri kertas 3) , keramik 4) , cat 5) , farmasi 6,7) , pengolahan minyak bumi 8) , dan pestisida 9,10) . Saat ini, kaolin yang diaktivasi dengan asam dan alumina telah digunakan juga untuk keperluan industri minyak nabati 11) .…”
Section: Casi3o8 + H2o + Co→ Al2o3 2sio2h2o + 4sio+ K2co3unclassified
See 1 more Smart Citation
“…Kaolin digunakan sebagai bahan baku di berbagai industri. Penggunaan kaolin yang terutama adalah di industri kertas 3) , keramik 4) , cat 5) , farmasi 6,7) , pengolahan minyak bumi 8) , dan pestisida 9,10) . Saat ini, kaolin yang diaktivasi dengan asam dan alumina telah digunakan juga untuk keperluan industri minyak nabati 11) .…”
Section: Casi3o8 + H2o + Co→ Al2o3 2sio2h2o + 4sio+ K2co3unclassified
“…2 S2O4 2-+ H2O ⇌ 2 HSO3 -+ S2O3 2- (8) Reaksi penguraian ini dipercepat oleh adanya oksigen dan pH yang rendah. Selain itu, reaksi penguraian ditionat juga dapat berlangsung menurut reaksi (3) pada pH 2 untuk kenaikan temperatur dari 70 o C menjadi 80 o C. Oleh karena pengaruh reaksi (4) dan (8), derajat keputihan yang diperoleh mengalami penurunan.…”
Section: Gambar 4 Hasil Pemutihan Pada Beberapa Temperatur Operasiunclassified
“…Several researchers investigated the performance and viability of various materials as molecular sieves, such as activated carbon [11] [12], kaolin clay [13], bentonite [14], fuller's earth [15], and even combined strategies [16]. Studies and product availability suggest fuller's earth may be the best all-around solution due to its high availability, low cost, and capacity for easy on-site reactivation of the absorbent [17] [18].…”
Section: Introductionmentioning
confidence: 99%
“…Comprehensive electrical and physical tests which include: color and appearance of oil, breakdown voltage, water content, acidity, dielectric loss factor, flash point, drop point, density, and eruption, and dielectric loss factor tests are not only used to measure the quality of TO but also to diagnose general incompatibilities of internal transformer components or transformer insulation system problems, which cannot be detected without a complete overhaul of the transformer. It is generally recommended that comprehensive electrical and physical tests be performed twice a year, insoluble gas analysis once a year, and eruption tests once every two years for transformers that have operated for more than five years [25][26][27][28].…”
Section: Introductionmentioning
confidence: 99%