Evaluation of mechanical properties of irradiated zirconium alloys in the vicinity of the metal-oxide interface

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 19 publications
0
5
0
Order By: Relevance
“…Further to the chemical analysis, the microstructure of the metal-oxide interface has been analysed in depth and it has been demonstrated that the 9-cycle oxide near the interface is much more porous, please refer to Figure 4. The role of porosity on the different properties of the oxide have been discussed by other authors and also in the laboratory [42], [19], [22], [23]. In a study performed previously, other researchers have shown that the porosity increases the resistivity of the oxide [42].…”
Section: Discussion Of Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Further to the chemical analysis, the microstructure of the metal-oxide interface has been analysed in depth and it has been demonstrated that the 9-cycle oxide near the interface is much more porous, please refer to Figure 4. The role of porosity on the different properties of the oxide have been discussed by other authors and also in the laboratory [42], [19], [22], [23]. In a study performed previously, other researchers have shown that the porosity increases the resistivity of the oxide [42].…”
Section: Discussion Of Resultsmentioning
confidence: 99%
“…The hydrogen pickup fraction of the cladding after 9 cycles had reached 30% compared to the 3-cycle cladding which was 17% [6]. This finding forms the basis for the motivation for the extensive characterisation and comparison of its high and low burnup samples [6], [19]- [23]. The advantage of this technique is the capability to measure the oxide conductivity at site specific regions of the material and provide the intrinsic properties of the region analysed.…”
Section: Introductionmentioning
confidence: 92%
“…section 3.2), a diameter of at least 40 µm is required to be representative of the investigated microstructures [53]. Secondly, an aspect ratio, defined as the ratio between the pillar height and its upper diameter, ranging between 2 and 3 is recommended in the literature for micro-compression testing [54,55].…”
Section: Porous Micro-pillarsmentioning
confidence: 99%
“…2a). In this frame, a special attention was paid to fulfil the geometrical recommendations regarding the specimen dimensions for accurate measurements (9,10). Indeed, as shown in Fig.…”
Section: Sample Preparationmentioning
confidence: 99%
“…The Ni swelling within the cermet generates high tensile stresses in the YSZ backbone leading to the apparition of micro-cracks (3). For classical anode supported cell, the mechanical damage of the ionic conducting phase within the cermet results in a substantial degradation of the overall cell performances (4)(5)(6)(7)(8)(9). It is therefore required to further enhance the hydrogen electrode robustness for a higher redox tolerance.…”
Section: Introductionmentioning
confidence: 99%