Evaluation of Origin Ensemble algorithm for image reconstruction for pixelated solid-state detectors with large number of channels

Abstract: The Voxel Imaging PET (VIP) Pathfinder project intends to show the advantages of using pixelated solid-state technology for nuclear medicine applications. It proposes designs for Positron Emission Tomography (PET), Positron Emission Mammography (PEM) and Compton gamma camera detectors with a large number of signal channels (of the order of 10). For PET scanners, conventional algorithms like Filtered Back-Projection (FBP) and Ordered Subset Expectation Maximization (OSEM) are straightforward to use and give goo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
4
2

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 16 publications
0
4
0
Order By: Relevance
“…We adopted SOE as an iterative algorithm without ML-EM (and advanced method of ML-EM), as well as the analytical method developed by Tomitani and Hirasawa. These methods have been used in previous comparison studies [28][29][30][31]. Nuclear medical images require the ability to PLOS ONE identify disease.…”
Section: Discussionmentioning
confidence: 99%
“…We adopted SOE as an iterative algorithm without ML-EM (and advanced method of ML-EM), as well as the analytical method developed by Tomitani and Hirasawa. These methods have been used in previous comparison studies [28][29][30][31]. Nuclear medical images require the ability to PLOS ONE identify disease.…”
Section: Discussionmentioning
confidence: 99%
“…Future work will include the improvement of the spatial resolution in all directions by further studies on rotating the Compton camera, the study on how to approximate the transition probability t ik and the sensitivity s j of the LM-OSEM algorithm and a systematic comparison of the performance of LM-OSEM and other algorithms for Compton camera (e.g. OE, as reported in [17]) with various phantoms. Additionally, it has to be studied how to diminish the artefacts in the edges and, especially, the corners of the images.…”
Section: Discussionmentioning
confidence: 99%
“…In our laboratory we have implemented it for 3-D PET data from a time-of-flight (TOF) list-mode lanthanum-bromide system [24] and for the Siemens Biograph 3-D PET [25]. We and other investigators have used it for analysis of data from a Compton camera and solid state detectors [26]–[28]. Other investigators have also used it in applications for radiotherapy [29].…”
Section: Discussionmentioning
confidence: 99%