2022
DOI: 10.1016/j.meddos.2021.12.002
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of patient-specific motion management for radiotherapy planning computed tomography using a statistical method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 16 publications
0
3
0
Order By: Relevance
“…The slight differences in positional coordinates between the lung tumor and fiducial markers were likely caused by complicated respiratory movements, including linear movement and looping and hysteresis curves [6] . Therefore, determining each patient’s optimal fiducial marker is important for accurately tracking the lung tumor and maximizing treatment quality using pretreatment 4DCT and 4D magnetic resonance imaging [9] , [14] .…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The slight differences in positional coordinates between the lung tumor and fiducial markers were likely caused by complicated respiratory movements, including linear movement and looping and hysteresis curves [6] . Therefore, determining each patient’s optimal fiducial marker is important for accurately tracking the lung tumor and maximizing treatment quality using pretreatment 4DCT and 4D magnetic resonance imaging [9] , [14] .…”
Section: Discussionmentioning
confidence: 99%
“…Four-dimensional computed tomography (4DCT) with a body surface infrared marker is useful to determine the movement of a lung tumor or fiducial marker before planning SBRT [9] . The 4DCT enables the measurement of lung volumes and evaluates the relationship of respiratory movements between lung volume and lung tumors.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, this study evaluated the amplitude difference between the lung tumor and fiducial markers using 4DCT, which may include uncertain underestimations and overestimations of respiratory movements and resolution limits of the phase numbers via 4DCT [19] . The spatial coordinates of the fiducial marker may be displaced during SBRT, and the amplitude difference between the lung tumor and fiducial marker should be observed during SBRT [20] . In the future, we believe that more robust and dynamic tracking during SBRT may be realized by combining magnetic resonance imaging and respiration by lung volume in addition to fiducial marker [9] , [12] , [21] , [22] .…”
Section: Discussionmentioning
confidence: 99%