“…In the analysis of the collected residual solid, the consumption rates of the fixed carbon and volatile were calculated using eqs and , respectively, to analyze the consumption of the volatile and fixed carbon during the PC combustion process. ,,− The burnout rate was calculated using eq to analyze the combustion efficiency of bituminous coal. ,,, Here, CR V and CR FC are the consumption rates (%) of the volatile and fixed carbon of the dry coal, respectively; V i , FC i , and A i (%) are the contents of the volatile, fixed carbon, and ash of the dry collected residual solid, respectively; V 0 , FC 0 , and A 0 (%) are the contents of the volatile, fixed carbon, and ash of the dry coal, respectively. Here, BR c (%) is the burnout rate of the bituminous coal; A i is the ash content of the collected residual solid, and A 0 is the ash content of the dry coal.…”