All Days 2008
DOI: 10.4043/19152-ms
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of PhaseWatcher Multiphase Flow Meter (MPFM) Performance in Sour Environments

Abstract: Accurate oil, water and gas flow rate measurements from individual wells are essential in order to properly manage both the wells and reservoirs, as well as to obtain reliable data for production performance monitoring, optimization, allocation and simulation models 1, 2, 3, 4, 5 . Over the past three decades, there has been great advancement in the multiphase metering technology. These advancements have resulted in a significant improvement in measurement accuracy as well as in reducing the physical size of t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2012
2012
2018
2018

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(1 citation statement)
references
References 3 publications
0
1
0
Order By: Relevance
“…A homogenization mechanism that removes all the possible regimes but the homogenous one such as the initial work of applying a dual-cell mix meter according to Hewitt et al (1995) [8] is an elegant strategy which leads to a uniform density distribution of the mixture across the pipe and then simplify the individual phase fraction measurement only by applying a radioactive source and a scintillation detector in front of each other on the pipe. 2009) also worked on this issue by the installation of a T-blind in the fluid flow direction and then redirecting the flow upward to reach favorable homogenization instead of implementing mixers in the pipeline [9][10][11].…”
Section: Measurement Strategymentioning
confidence: 99%
“…A homogenization mechanism that removes all the possible regimes but the homogenous one such as the initial work of applying a dual-cell mix meter according to Hewitt et al (1995) [8] is an elegant strategy which leads to a uniform density distribution of the mixture across the pipe and then simplify the individual phase fraction measurement only by applying a radioactive source and a scintillation detector in front of each other on the pipe. 2009) also worked on this issue by the installation of a T-blind in the fluid flow direction and then redirecting the flow upward to reach favorable homogenization instead of implementing mixers in the pipeline [9][10][11].…”
Section: Measurement Strategymentioning
confidence: 99%