2017
DOI: 10.1080/10916466.2017.1359624
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of physico-chemical properties of re-refined lubricating oils obtained from fabricated packed bed reactor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
2
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 10 publications
1
2
0
Order By: Relevance
“…The ULOs that were only subjected to temperatures of 80 and 100 °C did present a significant difference with respect to the control (P>0.05). Similar studies obtained a density of 0.87 g/cm 3 and from 0.87 to 0.91 g/cm 3 [26,27,28] which are important results, since these values of density, are an indication that they treatment processes have removed contaminants from the ULOs. The previous results exceed those found in this study which was 0.84 g/cm 3 , but it is slightly above the value of commercial diesel which has a density of 0.83 g/cm 3 [29] and is used to prepare oil-based drilling fluids [14].…”
Section: Ulos Densitysupporting
confidence: 59%
“…The ULOs that were only subjected to temperatures of 80 and 100 °C did present a significant difference with respect to the control (P>0.05). Similar studies obtained a density of 0.87 g/cm 3 and from 0.87 to 0.91 g/cm 3 [26,27,28] which are important results, since these values of density, are an indication that they treatment processes have removed contaminants from the ULOs. The previous results exceed those found in this study which was 0.84 g/cm 3 , but it is slightly above the value of commercial diesel which has a density of 0.83 g/cm 3 [29] and is used to prepare oil-based drilling fluids [14].…”
Section: Ulos Densitysupporting
confidence: 59%
“…The results of flash point are also related to oxygen materials, which have a higher percentage in used lubricating oil due to the presence of aldehydes and ketones. (Whose locations were determined from the FTIR) that these substances reduce the flash point [4], [31].…”
Section: Flash Pointmentioning
confidence: 99%
“…[ 8 , 9 ]. Hydrofining technology is one of the most common technologies for the recycling of spent lubrication oil [ 10 , 11 , 12 ]. It possesses many advantages, such as a large treatment capacity, high recovery rate, good product quality, etc., despite its huge initial input costs.…”
Section: Introductionmentioning
confidence: 99%