2020
DOI: 10.1128/jcm.00159-20
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of QuantiFERON-TB Gold Plus on Liaison XL in a Low-Tuberculosis-Incidence Setting

Abstract: T he QuantiFERON-TB Gold Plus assay (QFT; Qiagen, Hilden, Germany) is a frequently used interferon gamma releasing assay (IGRA) for the diagnosis of latent tuberculosis infections (LTBI) (1, 2). Recently, it became available on Liaison XL (DiaSorin S.p.A., Saluggia, Italy), a fully automated analyzer using chemiluminescense detection within a chemiluminescent immunoassay (CLIA). In this study, we compared this novel method to the commonly used enzyme-linked immunosorbent assay (ELISA) in a low-incidence LTBI s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
12
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(14 citation statements)
references
References 2 publications
2
12
0
Order By: Relevance
“…Linear regression analysis indicated substantial correlation between ELISA and CLIA despite the two different methods of measurement; however, CLIA produced significantly higher values both for TB1 and TB2 than ELISA. This is in agreement with previous data on CLIA performance in a smaller study population (11). In our opinion, this difference is not due to preanalytical factors but rather to the intrinsic chemistry of the assay based on chemiluminescence technology with paramagnetic microparticle solid phase, allowing the detection of very low levels of IFN-␥ (13,19).…”
Section: Discussionsupporting
confidence: 92%
See 2 more Smart Citations
“…Linear regression analysis indicated substantial correlation between ELISA and CLIA despite the two different methods of measurement; however, CLIA produced significantly higher values both for TB1 and TB2 than ELISA. This is in agreement with previous data on CLIA performance in a smaller study population (11). In our opinion, this difference is not due to preanalytical factors but rather to the intrinsic chemistry of the assay based on chemiluminescence technology with paramagnetic microparticle solid phase, allowing the detection of very low levels of IFN-␥ (13,19).…”
Section: Discussionsupporting
confidence: 92%
“…CLIA repeatability and reproducibility on this platform were studied by Brantestig et al, who found that the imprecision of the method is within an acceptable range and analysis of linearity showed acceptable recovery (12). Furthermore, a recent study by De Maertelaere et al conducted on 92 samples showed that CLIA gave significantly higher values for TB1 and TB2 than ELISA (11).…”
mentioning
confidence: 98%
See 1 more Smart Citation
“…To overcome the deficiencies of the TST, IGRAs have been developed as an alternative immunodiagnostic approach. Thus far, there are five commercialized IGRA kits, including the T-cell spot of the TB assay (T-SPOT.TB, Oxford Immunotec, Abingdon, UK), QuantiFERON-TB Gold In-Tube (QFT-GIT, Qiagen GmbH, Hilden, Germany), QuantiFERON-TB Gold-Plus (QFT-Plus, Qiagen, MD, United States), LIAISON QuantiFERON-TB Gold Plus (LIAISON QFT-Plus, DiaSorin S.p.A., Italy), and LIOFeron TB/LTBI (LIONEX GmbH, Braunschweig, Germany) (De Maertelaere et al, 2020;Della Bella et al, 2020;Altawallbeh et al, 2021;Hamada et al, 2021). In addition, there are five products in development-T-Track (R) TB (Lophius Biosciences GmbH), VIDAS TB-IGRA (bioMérieux), Access QuantiFERON-TB (Boditech Med Inc.), ichroma TM IGRATB (Boditech Med Inc.), and IP-10 IGRA elisa/lateral flow (rBioPharm) (WHO, 2020).…”
Section: Interferon-gamma Release Assaysmentioning
confidence: 99%
“…However, the QFT-Plus performance within endemic settings has been documented less. Nonetheless, comparative data on the performance of QFT-GIT and QFT-Plus in LTBI detection are largely based on middle or low TB-incidence settings 7 , 16 18 . Therefore, we aim to compare the two tests in Thailand, where the TB burden is high.…”
Section: Introductionmentioning
confidence: 99%