Evaluation of semi-automatic image analysis tools for cerebrospinal fluid electrophoresis of IgG oligoclonal bands

Abstract: BackgroundIgG concentrations in cerebrospinal fluid generally range from 20 to 45 mg/L. In multiple sclerosis immune reactions lead to intrathecal synthesis of specific IgGs that can be detected in biological fluid samples both quantitatively and qualitatively by isoelectric focusing of supplementary oligoclonal IgG bands.MethodA simple tool, using the MATLAB application, to facilitate and improve isoelectric focusing profile analysis is presented and evaluated in terms of its sensitivity, repeatability and re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 16 publications
0
2
0
Order By: Relevance
“…The synthetic lane background was generated by randomly choosing one of five real negative grayscale profiles (i.e., profiles without OCBs) filtered beforehand with a two-dimensional (2D) Gaussian filter. Gaussian functions are commonly used in the literature to approximate band shapes [ 10 , 18 ] hence, the bands were created using a Gaussian density function. The expected value was the band position, and the standard deviation (SD) was proportional to the band width (band width 4 .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The synthetic lane background was generated by randomly choosing one of five real negative grayscale profiles (i.e., profiles without OCBs) filtered beforehand with a two-dimensional (2D) Gaussian filter. Gaussian functions are commonly used in the literature to approximate band shapes [ 10 , 18 ] hence, the bands were created using a Gaussian density function. The expected value was the band position, and the standard deviation (SD) was proportional to the band width (band width 4 .…”
Section: Methodsmentioning
confidence: 99%
“…We are currently developing the first automatic tool for OCB detection in CSF and tear samples [ 9 , 10 , 11 ]. Our objective is to provide an easy-to-use solution with a reasonable processing time, to ensure its adoption by hospital physicians.…”